. • <br /> Page 4 of 4 Advantage Contractors 01.28.2016 <br /> SCOPE OF WORK: <br /> 1. Head flash windows and all miscellaneous penetrations with pre-finished 24-gauge metal flashings(with bent end-dams). <br /> 2. Cover the top of all flashings with flexible flashing("Grace's Vicor") per manufacturer spec and industry standard. <br /> 3. Install new water-resistive-barrier, integrate with fiashings ("Jumbo-Tex" 60-minute paper) per manufacturer's specification. <br /> � 4. Install new tight-knot cedar vertical and horizontal trim at inside and outside corners and window perimeters. <br /> 5. Install lames Hardie's"Hardi-Plank HZ-10" ,horizontal lap courses with flashing at each joint, per manufacturer's specification. <br /> 6. Install new metal flashing(coping) at roof parapet wall and integrate into existing roofing and adjacent walls. <br /> 7. Seal all siding to trim joints with "Quad" (OSI Sealants)caulking. <br /> 8. Garage inset walls(indicated with green dash box in photo above) not included in scope. <br /> 9. East inset walls/soffit ceiling(indicated by red arrows in photo above) not included in scope. <br /> 10. Corrugated fiberglass roof panels (as indicated by red dash box in photo above) not included scope. <br /> � 11. Paint all new installations to match existing building colors(separate contract). <br />