Laserfiche WebLink
. { <br /> 15. Wall sheathu g shall be APA Rated,exterior or exposure 1 plywood,in conformance with <br /> UBC Standard No.23-2. APA raterl,Exterior or Exposure] Oriented Strand Board <br /> (OSB),in conformance with UBC£tandard No.?33 may be used 'ut lieu of plywood at <br /> interior verdcal surfaces only. She;ithing shall be manufactured under the provisions of <br /> Voluntary Product Standards P�i-95 or ps2-92,or APA PRP-108 Performance Standzrds <br /> and Policies for Structural Use Panels. See drawings for thickness,span rating,and <br /> nailing requirements. Unless otherwise noted,wall sheathing shall be 1/2" (nominal) <br /> with span rating of 24/0. Glue floor sheathing to all supporting members with adhesive <br /> conforming to APA Specificadon AFG-Ol. <br /> 16. All wood plates in d'uect contact with concrete or masonry shall be pressure-treated with <br /> an approved preservative.Provide 2layers of asphalt-impregnated building paper <br /> between untreated ledgers,blocking,ek.,and concrete or masonry. <br /> 17. Timber connectors called out by letters and numbers shall be"Strong-Tie"l.y Simpson <br /> Company,as specified in their Catalog No.C-2002. Altemate conner.tors may be used <br /> subject to review and approval by the structural engineer. A current NER or ICBO report <br /> and a list stating the item-for-item substitution must be submitted to the structural <br /> engineer for any proposed substitutes. The contractor shall be responsible for all <br /> engineering costs relating to review and/or re-design to accommodnte proposed <br /> substitutions. Provide number and size of fasteners as specified by manufacturer. <br /> Connectors shall be installed in accordance with the manufacturer's instructions. All <br /> bolts in wood memUers shall conform to ASTM A307. Provide washers under the heads <br /> and nuts of all bolts and lag screws bearing on wood. All shims shall be seasoned and <br /> dried and the same grade(minimum)as members connected. All joists and multiple joist <br /> beams shall be connected to flush beams with"IiU"series joist hangers,unless otherwise <br /> noted. <br /> 18. Wood framing notes: the following apply unless otherwise noted on the drawings: <br /> a. All wood framing details shall be constructed to the minimum standards of the <br /> UBC.Minimum nailing shall conform to UBC Table 23-II-B-1 or current ICBO <br /> Report NER-272. Provide washers under the heads and nuts of all bolts and lag <br /> screws bearing on wood. Installation of lag screws shall conform to 1991 ND5 <br /> Seclion 9.1.2,and installation of bolts shall conform to 1991 NDS Section 8.1.2. <br /> b. Nailing: All nails specified on the drawin�s were designed to be galvanized box <br /> ot power driven nails. Minimum nail diameter and length shall be as follows: <br /> Box Nails Po�ver Driven E uivalent <br /> Sheathin NaiLs Sd 0.131"x 21 4" <br /> lOd 0.148"x 21 2" <br /> Framin Nails lOd 0.148"x 3" <br /> 16d 0.148"x 31 4" <br /> �3 <br />