• • • <br /> Your equipment is covered by a LIMITED WARRANTY against In all cases, the equipment MUST be installed in accordance <br /> defects in material and workmanship. with the installation instructions described in this manual. <br /> This is a vertical, wallmount unit designed for many different ' WARNING: IMPROPER INSTALLATION MAY <br /> applications in both residential and commercial settings. It is DAMAGE EQUIPMENT, CAN CREATE A <br /> self-contained and arrives completely assembled, factory- ' HAZARD AND WILL VOID THIE WARRANTY <br /> charged and wired. The unit is 100% run-tested at the factory to <br /> ensure proper operation. Your unit is supplied with high-quality � . _ � � <br /> copper tubing and enhanced aluminum-finned coils for high heat <br /> transfer efficiency and long life. The unit cabinet is constructed <br /> of G-90 galvanized steel.All exterior surfaces are finished with a If heating and cooling functions are controlled by separate <br /> baked-on polyester coating. This will provide excellent corrosion thermostats, turn the furnace thermostat to the "OFF" position <br /> protection in most applications. However, if the unit is installed during the cooling season to prevent simultaneous operation of <br /> in an area with a corrosive atmosphere, such as near an the heating and cooling systems. Reverse the procedure during <br /> industrial plant or on the seacoast, additional coating should be the heating season. <br /> considered to extend the life of the coils and cabinet. <br /> If the same thermostat controls both heating and cooling <br /> This unit was designed for up to 105°F of ambient temperature functions, set the thermostat to either HEAT or COOL as <br /> for the cooling mode; for heating mode, this unit was designed desired. <br /> for up to 78°F of room temperature and minimum 15°F ambient <br /> temperature. Set the desired temperature on your thermostat and set the fan <br /> switch to "ON" (for continuous air circulation) or to <br /> � � � "AUTOMATIC" (for air circulation only when the heat pump <br /> system is operating). <br /> A thorough inspection of the shipping container should be made <br /> immediately upon receiving your unit. Look for any punctures or IMPORTANT: Wait at least three (3) minutes after turning the <br /> openings. If it appears as if damage has occurred, it should be air conditioner off before trying to restart. If an attempt is made <br /> noted on the freight bill before signing. The delivering carrier to start the compressor before the refrigerant pressures are <br /> should be contacted immediately to inspect damage, and no equalized, the compressor motor may trip on its overload. An <br /> installation work should begin until this inspection is completed. additional waiting period will be required before restarting. <br /> DANGER: BEFORE PERFORMING ANY � � <br /> WORK ON THIS EQUIPMENT, POWER SUPPLY <br /> ■ MUST BE TURNED OFF AT THE HOUSEHOLD 1. Always install and keep filters clean. Check filters every 2 <br /> SERVICE BOX TO AVOID THE POSSIBILITY OF Weeks. Clean or replace if necessary. The factory-installed filter <br /> SHOCK, INJURY, DEATH,OR DAMAGE TO EQUIPMENT. is located behind the center front access panel. <br /> TO CHANGE SYSTEM FILTER: <br /> A. Turn the power to the unit off at the unit disconnect. The <br /> disconnect is located on the front of the T Series unit <br /> WARNING: Fai�uRE TO FOLLOW THESE behind a small access door. <br /> ' RULES AND INSTRUCTIONS COULD CAUSE A B. Remove the front center access door from the unit. <br /> . MALFUNCION OR DESTRUCTION OF C. Remove and replace the flter with the type and size <br /> EQUIPMENT WHICH COULD RESULT IN indicated in the table below. <br /> PROPERTY DAMAGE, SERIOUS BODILY INJURY, OR D. Replace the access door and turn on the power to the <br /> DEATH. unit. <br /> 1. Installation and repair MUST be done by a qualified NOTE: If your system has a filter grille installed in the return air <br /> person. The equipment should be inspected before use opening, the unit filter should have been discarded during <br /> and at least once annually by a professional service installation. <br /> person. <br /> 2. AVOID ELECTRICAL SHOCK! Turn power OFF when The filter installed into the return air grille assembly should be <br /> servicing. There may be more than one disconnect replaced with the same size and type provided with the grille. <br /> switch to de-energize unit. <br /> 3. Close cover(s) before returning breaker(s) to "ON" If your system is equipped with a fresh air intake, the filter for <br /> position. the fresh air assembly is accessed through the front center <br /> 4. Please observe good safety practices by wearing panel. The filter is a permanent washable type. <br /> personal protective equipment such as gloves and safety <br /> glasses to avoid injury. UNIT MODEL QTY. FILTER SIZE TYPE <br /> 5. Installation MUST conform to local codes. In the absence 36 1 16 x 30 x 1 standard Dis osable <br /> of local codes, refer to the National Electrical Code 36 1 16 x 30 x 2 o tional Pleated <br /> (NEC), ANS/NFPA No. 70-1993 and recommendations 48,60 1 20 x 30 x 1 standard Dis osable <br /> made by the National Board of Fire Underwriters. 48,60 1 20 x 30 x 2 o tional Pleated <br /> In our continuing effort to improve our product, specifications WARNING: SERIOUS INJURY MAY RESULT <br /> may change without notice. If there are any questions, please IF WATER SPRAY IS DIRECTED TOWARD LIVE <br /> see the contact information on the last page of this manual. ' ELECTRICAL CONNECTIONS OR POWER <br /> REV. 3/13/14 3090013 <br /> " /� <br />