My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3601 COLBY AVE 2018-02-01
>
Address Records
>
COLBY AVE
>
3601
>
3601 COLBY AVE 2018-02-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2018 9:05:16 AM
Creation date
1/8/2018 9:43:15 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3601
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• ` <br /> .. , 2015 Washington State Ener Code Compliance Forms for Commercial, R2 a R3 over 3 stories and all R1 <br /> . • • - • • • • • <br /> 2015 Washin ton State Ener Code Com liance Forms for Commercial Buildin s includin R2&R3 over 3 stories and all R1 Revised Janua 2017 <br /> Project Title: Date 1/1/2015 <br /> ECONOMIZER EXCEPTIONS-NEW CONSTRUCTION AND ADDITIONS,CONTINUED <br /> Economizer Exp 10 Cooling equipment for dedicated server,electronic epuipment or Compliance Cooling <br /> telecom switch rooms. Per building limit for this exception is System ID Option Capacity <br /> Exception 240,000 Btu/h cooling capacity or 10/o of required building air Btu/h <br /> Summary economizer capacity,whichever is greater. Part load control <br /> required over 85,000 Btu/h.Additional requirements apply. <br /> Option a- Cooling equipment e�ciency shall be 15%better than the <br /> WSEC required minimum efficiency.. <br /> Option b- Waterside economizer required.Cooling equipment <br /> efficiency shali be 5%better than the WSEC required <br /> minimum efficiency. <br /> Option c- Waterside economizer required.All cooling equipment is <br /> subject to ASHARE Standard 127. Total Claimed Exempt Capacity: <br /> Reier to Section Total building air economizer capacity(if claimed>240 kBtu/h): <br /> C403.3 for <br /> descriptions of Alternate Exp 10 Capacity Limit: <br /> economizer ECONOMIZER EXCEPTIONS-MECHANICAL SYSTEM ALTERATIONS OR REPLACEMEN S stem ID Alt.Strate <br /> provisions and <br /> exceptions. For C503.4 Pre-approved design alternative to full compliance with air economizer <br /> alterations refer Exp 1 requirement.An a►ternative for mechanical system alterations where existing <br /> to Section building constraints make full compliance with air economizer requirement <br /> C503.4 and impractical.Provide calculations to the code o�cial that demonstrate the <br /> Table C503.4. proposed alternate design strategy provides similar energy savings to the <br /> annual energy that would be saved by the cooling system with air economizer <br /> per C403.3. <br /> ECONOMIZER EXCEPTIONS-SIMPLE SYSTEMS Cooling <br /> C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h.Per System ID Capacity <br /> Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5%of BtWh <br /> required building air economizer capacity,whichever is greater.Cooling <br /> equipment efficiency shall be 15%better than WSEC required minimum <br /> efficiency.Not eligible:non-unitary equipment,unitary equipment installed <br /> outdoors or in mech room adjacent to outdoors,equipment installed during <br /> new construction,shell-and-core construction,or initial tenant <br /> improvement. <br /> Total Claimed Exempt Capacity: <br /> Total building air economizer capacity(if claimed>72,000 Btu/h): <br /> Alternate C503.4 Exp 2 Capacity Limit: <br /> C5U3.4 Equipment that provides hydronic chilled water for chilled water termina! Cooling <br /> Exp 3 units.Equipment part load cooling efficiency(IPLV)shall be better than System ID Capacity <br /> WSEC required minimum efficiency by at least 25%.Per building limit Btu/h <br /> for this exception is 480,000 Btu/h cooling capacity or 20%of required <br /> building air economizer capacity,whichever is greater.Chilled water <br /> terminal units serving Group R occupancies are not included in the <br /> building capacity total. <br /> Total Claimed Exempt Capacity: <br /> Total building air economizer capacity(if claimed>480,000 Btu/h): <br /> Alternate C503.4 Exp 3 Capacity Limit: <br /> Table ComplianceOptionsforalterationorreplacementofexisting SystemlD Equipment Compliance <br /> C503.4 mechanical cooling equipment per Table C503.4. Refer to table T e Path <br /> and all applicable table footnotes for full requirements.Applies to <br /> the following retrofit conditions: <br /> Option a-Any new or replacement equipment <br /> Option b-Replacement equipment of same type with same or <br /> smaller cooling output capacity. <br /> Option c-Replacement equipment of same type with large <br /> cooling output capacity. <br /> Option d-New equipment added to existing system or <br /> replacement equipment that is different than existing <br /> being replaced. <br /> I�l l '� i <br />
The URL can be used to link to this page
Your browser does not support the video tag.