My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2818 HEWITT AVE KATANA SUSHI 2018-01-09
>
Address Records
>
HEWITT AVE
>
2818
>
KATANA SUSHI
>
2818 HEWITT AVE KATANA SUSHI 2018-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2018 9:09:34 AM
Creation date
1/9/2018 9:09:27 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2818
Tenant Name
KATANA SUSHI
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� • • <br /> PUBL/C I�l/O/,?J�S <br /> ENGINEERING /PUBLIC SERVICES DEPARTMENT <br /> October 27, 2015 <br /> Allisa Hui <br /> allisahui@yahoo.com <br /> RE: Owner: Big Lund LLC <br /> Job Address: 2818 Hewitt Ave <br /> Plan Check No: M1510-060 <br /> Dear Allisa, <br /> In response to your application for a Type 1 Hood, your plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. These comments address building issues only. Additional <br /> revisions, or additions, may be required by other departments (such as Utilities, Planning or <br /> Fire). All references refer to the 2012 International Building Code (IBC), the 2012 International <br /> Fire Code (IFC), the 2012 International Mechanical Code (IMC), and the 2012 International <br /> Energy Conservation (IECC), as amended by the State of Washington and adopted by the City <br /> of Everett. The current IBC referenced standard for accessible design is the 2009 "Accessible <br /> and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA regulations and standards <br /> may be more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of construction <br /> documents reflecting the corrections requested. <br /> 1. Please include the cooking appliances. <br /> 2. The plans should include the requirement for a grease duct leak test in <br /> accordance with IMC 506.3.2.5. <br /> 3. The exhaust outlet termination should be dimensioned at 40 inches minimum <br /> above the roof. IMC.506.3.13.1. <br /> 4. The hood must be designed for thorough cleaning and grease removal in <br /> accordance with IMC 507.8 and 507.11. <br /> 5. A minimum clearance to combustible framed walls and ceilings of 18 inches is <br /> required per IMC 507.9 or 6 inches per IMC 308. <br /> 6. The hood canopy overhang of 6 inches should be indicated per IMC507.12. <br /> 7. A 10ft separation is required between the exhaust outlet and the makeup air <br /> intake. IMC 506.3.13.3. <br /> If you have any questions, please call me at 425-257-7264. <br /> IT VER • .� r tr t • Everett WA 98201 • 425 257-8200 • Fax 425 257-8856 I � " <br /> C Y O F E E T T 2 0 0 C e d a S e e , � <br /> S-VICoinmunAC�uricbdASMillerA2818 Hewut Avc(MI510-060).doc � � � � � _ .. <br />
The URL can be used to link to this page
Your browser does not support the video tag.