My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2818 HEWITT AVE KATANA SUSHI 2018-01-09
>
Address Records
>
HEWITT AVE
>
2818
>
KATANA SUSHI
>
2818 HEWITT AVE KATANA SUSHI 2018-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2018 9:09:34 AM
Creation date
1/9/2018 9:09:27 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2818
Tenant Name
KATANA SUSHI
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL REGULATIONS <br /> TABLE 308.6 <br /> CLEARANCE REDUCTfON METHODSb <br /> REDUCED CLEARANCE WITH PROTECTION(inches)a <br /> Horizontal combustible assemblies <br /> Horizontal combustible assemblies located beneath the heat source and all <br /> located above the heat source vertical combustible assemblies <br /> Required clearance to combustibles Required clearance to combustibles <br /> without protection(inches)a without protection(inches) <br /> TYPE OF PROTECTIVE ASSEMBLYa 36 18 9 6 36 18 9 6 <br /> �! Galvanized sheet steel,having a minimum thickness of 0.0236 inch(0.6010 mm)(No. 18 9 5 3 12 6 3 3 <br /> �,r� 24 gage),mounted on 1-inch glass fiber or mineral wool bat[reinforccd with wirc on <br /> � thc back,I inch off the cornbustible assembly <br /> Galvanized sheet s[eel,having a minimum thick�ess of 0.023G inch(0.(O10 mm)(No. 18 9 5 3 12 6 3 2 <br /> 24 gage),spaced 1 inch off the combustible assembly <br /> Two layers of galvanized sheet stccl,having 1 minimum thickness of 0.0236 inch 18 9 5 3 12 6 3 3 <br /> (0.6010 mm)(No.24 gage),having a 1-inch airspace between laycrs,spnced 1 inch <br /> off tl�c comhustible assembly <br /> Two layers of galvanized shcet steel,having a minimum tl�ickness of 0.0236 inch 18 9 5 3 12 6 3 3 <br /> (O.6010 mm)(No.24 ga�e),having 1 inch of fiberglass insulation between layers, <br /> spaced 1 inch off the combustible assembly <br /> 0.5-inch inorganic insulating board,over I inch of fiberglass or mineral wool batt, 24 12 6 4 18 9 5 3 <br /> against the combustible assembly <br /> 3'1z inch brick wall,spaced 1 inch off the combustible wall — — — — 12 6 6 6 <br /> 3��,-inch brick wall,a�ainst fhc comhn,ttible wall -- 24 7? 6 5 <br /> -- --- --- ---- — - �-- ----- —� — ------------------ ---- ---.. . ----... <br /> For SI: 1 inch=25.4 mm,°C=[(°F)-32]l1.8,1 pound per cubic foot=16.02 kg/m3,1.0 Btu•in/ftZ•h•°F=0.144 W/m2•K. <br /> a. Mineral wool and glass fiber batts(blanket or board)shall have a minimum density of 8 pounds per cubic foot and a minimum melting point of 1,500°F. <br /> lnsulation material utilized as part of a clearance reduction system shall have a thermal conductivity of 1.0 Btu•in/(ft2•h•°F)or less.Insulation board shall <br /> be formed of noncombustible material. <br /> b. For limitations on clearance reducrion for solid fuel-burning appliances,masonry chimneys,connector pass-throughs,aiasonry fire places and kitchen ducts, <br /> see Sections 308.7 through 308.11. <br /> �� <br /> [F] SECTION 311 <br /> SMOKE AND HEAT VENTS <br /> [F'] 31L1 Required.Approvecl smoke and heat vents shall be <br /> installed in the roofs of one-story buildings where required by <br /> the Internritional Fire Co�le. Smoke and heat vents shall be <br /> designed and installed in accordance with the International <br /> Fire Code. <br /> SECTION 312 <br /> HEATING AND COOLING LOAD CALCULATIONS <br /> 3121 Load calculations.Heating and cooling system design <br /> loads for the purpose of sizing systems,appliances and eyuip- <br /> ment shall be determined in accordance with the procedures <br /> described in the ASHRAE/ACCA Standard 183. Alterna- <br /> tively, design loads shall be determined by an approved <br /> equivalent computation procedure, using the design parame- <br /> ters specified in Chapter 3 of the International Energy Con- <br /> servation Code. <br /> 2012 GN�"�F�EVIdl-10[VAL M�C@-9,r1NICAL CUD��" 29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.