My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2818 HEWITT AVE KATANA SUSHI 2018-01-09
>
Address Records
>
HEWITT AVE
>
2818
>
KATANA SUSHI
>
2818 HEWITT AVE KATANA SUSHI 2018-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2018 9:09:34 AM
Creation date
1/9/2018 9:09:27 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2818
Tenant Name
KATANA SUSHI
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
April 12, 2016 <br /> BIGLj.JND LLC <br /> 2818 Hewitt Ave <br /> Katana Sushi <br /> Type I Hood <br /> Permit: M 1510-060 <br /> Corrections letter: <br /> 1) Remove wood framing above hood and 18" in all directions from the <br /> hood. Replace with non-combustible framing materials above hood and 18" <br /> in all directions of the hood. You may use one of the clearance reduction <br /> methods in Table 308.6. Inspector will need to verify the non-combustible <br /> wall framing and the non-combustible overhead framing before you cover. <br /> 5079 IMC-A Type I Hood shall be installed with a clea�ance to <br /> combustibles of not less than 18 inches. Table 308.6 allows for a �eduction <br /> to the 18"clearance. <br /> 2) The grease duct wrap is not installed per the manufacturer's specs. <br /> Remove the wrap and call for a light test inspection before you re-install the <br /> 3M Wrap. Remove the spray foam around the grease duct wrap at the roof <br /> level. After the light test inspection you can re-install the fire wrap following <br /> the manufacturer's instructions. Please call for inspection of the fire wrap. <br /> 3) Install hangers on the make-up air. <br /> SI0.9 IMC—Ducts shall be supported at inte�vals not exceeding 1 D feet. <br /> Supports shall be const�uct�c�'of nonco�nUustible mater•ial. <br /> 4) Location of the fan is not code compliant. <br /> 506.3.13.3 IMC—Exhaust outlets shall be located not less than 10 feet <br /> ho�izontally fi�om pa��ts of the saine o� contiguous buildings, adjacent <br /> buildings and adjacent p�ope�ty lines and shall be located not less than 10 <br /> feet above the adjoining grade level. Exhaust outlets shall be located not less <br /> tltan 10 feet ho�izontally from o� not less than 3 feet above ai� intake <br /> openings into any building. <br /> Exception: Exhaust outlets shall te�minate not less than S feet horizontally <br /> from pa�ts of the same or� contiguous building, an adjacent building, <br /> adjacent prope�ty line and ai� intake openings into a building whe�e air <br /> f�orn the exhaust outlet discha�ges away f�om such locations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.