Laserfiche WebLink
, <br /> ` � General Data o <br /> MODEL TUHiC100A9H41 B, VENT PIPE DIAMETER—Min.(inJ 00 3 Round <br /> TYPE Upflow/Horizontal HEAT EXCHANGER <br /> RATINGS O <br /> Input BTUH O 97,000 Type-Fired Alum.Steel <br /> Capacity BTUH(ICS) O 92,105 -Unfired <br /> AFUE 95.0 Gauqe(Fired) 20 <br /> ORIFICES—Main <br /> Temp.rise(Min.-Max.)°F. 35-65 Nat.Gas.Qty.—Drill Size 5—45 <br /> BLOWER DRIVE O DIRECT L.P.Gas Qtv.—Drill Size 5—56 <br /> Diameter-Width(In.) 11 x 10 GAS VALVE Redundant-Sinqle Staqe <br /> No.Used 1 PILOT SAFETY DEVICE <br /> Speeds(No.) 4 T�pe Hot Surface Iqnition <br /> CFM vs.in.w.g. See Fan Performance BURNERS—Type Multiport Inshot <br /> Motor HP O 3/4 Number 5 <br /> R.P.M. 1100 pOWER CONN.—V/Ph/Hz O 115/1/60 <br /> Volts/Ph/Hz 115/1/60 Ampacity(In Amps) 11.4 <br /> FLA 8.4 Max.Overcurrent Protection(amps) 15 <br /> COMBUSTION FAN-Type Centrifugal pIPE CONN.SIZE(IN.) 1/2 <br /> Drive-No.Speeds Direct-1 DIMENSIONS H x W x D <br /> Motor HP-RPM 1/20-3450 Crated(In.) 41-3/4 x 23 x 30-1/2 <br /> Volts/Ph/Hz 115/1/60 Uncrated(In.) 40 x 21 x 28-1/2 <br /> F.L.Amps •�� WEIGHT <br /> FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 171/160 <br /> Type Recommended High Velocity <br /> Hi Vel.(No.-Size-Thk.) 1 -20x25-1in. <br /> O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. <br /> O For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for eievations above 2,000 feet above sea level. <br /> For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. <br /> O Based on U.S.government standard tests. <br /> O The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. <br /> O Constant torque ECM blower motor <br /> OO Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. <br /> OO All TUH1 and TDH1 furnace models have a vent outlet diameter that equals 2". <br /> OO 4 Speed,direct drive X13 style high efficiency DC motor <br /> Mechanical Specifications <br /> NATURALGASMODELS—Centralheating ENERGYEFFICIENT OPERATION STYLING—Heavygaugesteeland"wrap- <br /> furnace designs are certified to ANSI Z21.47 Furnace is certified to leak 2% or less of around" cabinet construction is used in <br /> /CSA 2.3 for both natural and L.P.gas. Limit nominal air conditioning CFM delivered the cabinet with baked-on enamel finish for <br /> setting and rating data were established and when pressurizedto.5"watercolumnwith strength and beauty. The heat exchanger <br /> approved under standard rating conditions all inlets, outlets, and drains sealed. sectionofthecabinetiscompletelylinedwith <br /> using American National Standards Institute INTEGRATED SYSTEM CONTROL— foil-faced fiberglass insulation. This results <br /> standards. in quiet and efficient operation due to the <br /> Exciusively designed operational program excellent acoustical and insulating qualities <br /> SAFE OPERATION—The Integrated System provides total control of furnace limit sen- of fiberglass. <br /> Control has solid state devices,which continu- sors, blowers, gas valve, flame control and <br /> ously monitorfor presence of flame,when the includes self diagnostics for ease of service. FEATURES AND GENERAL OPERA- <br /> system is in the heating mode of operation. The built-in, selectable "Cooling Fan Off" TION—These High Efficiency, Direct Vent, <br /> Slow opening,dual solenoid combination gas feature provides time-delay capability like Condensing Gas Furnaces employ a Hot <br /> valve and regulator provide extra safety and a BAY24X045 Time-Delay Kit for cooling Surfacelgnitionsystem,whicheliminatesthe <br /> quieter operation. operation. Also contains connection points waste of a constantly burning pilot.They are <br /> QUICK HEATING— Durable, cycle tested, for E.A.C./humidifier. convertible for HORIZONTAL use by rotat- <br /> ing the unit to its right side. The integrated <br /> heavy gauge aluminized steel heat ex- AIR DELIVERY—The multispeed, direct- system control lights the main burners upon <br /> changer and stainless steel secondary drive blower motor, with sufficient airflow <br /> a demandforheatfromthe room thermostat. <br /> heat exchanger quickly transfer over 90%of range for most heating and cooling require- Complete front service access. <br /> the heat to provide warm conditioned air to the ments, will switch from heating to cooling <br /> structure. Low energy power vent blower, speeds on demand from room thermostat. a. Low energy power venter. <br /> to increase efficiency and provide a positive Theblowerdoorsafetyswitchwillpreventor b. Vent proving differential switch. <br /> dischargeofgasfumestotheoutsideasitdraws terminatefurnaceoperationwhentheblower <br /> outdoor air in for sealed combustion, which doorisremoved.(Fan relayand35VAcontrol <br /> means it uses no indoor air for combustion. transformer is standard). <br /> BURNERS—Multi-port, in-shot burners will Library Unitary <br /> give years of quiet and efficient service. All Product Section Furnaces <br /> models can be converted to L.P.gas without Product Furnace <br /> changing burners. Mode� TUH1 <br /> Literature Type Submittal <br /> Technical Literature-Printed in U.S.A. /'}'1 Sequence - <br /> Ingersoll Rand c �I I us Date 04/15 <br /> 6200Troup Highway <�srE9 File No. TUH1C100-H-SUB-iC <br /> Tyler,TX 75707 Intertek Supersedes TUH1C100-H-SUB-1 B <br /> The Manufacturer has a policy of continuous product and product da[a � <br /> improvement and reserves the right to change specifications and design ,.� j� <br /> without notice. . - � <br />