Laserfiche WebLink
, • • • <br /> Mechanical Specifications <br /> General These coils are A.R.I.certified with American <br /> Upflow, Downflow, or Horizontal coils shall be designed for cooling and heat Standard Heating&Air Conditioning's matching <br /> pump applications. The coil shall be 3/8"seamless aluminum tubing me- condensing units. <br /> chanically bonded to aluminum plate fin. Accessories <br /> Refrigerant for the 4TXC-DS coils shall be controlled with factory installed Evaporator Defrost Control installed on coil for <br /> Non-Bleed TXV refrigerant control. Refrigerant connections are brazed fit- lower ambient operating conditions. <br /> tings with an additional Schrader Valve for system service. <br /> The coil cabinet shall have a removable front and interior access panel for <br /> evaporator coil entering air surface cleaning. <br /> The coil includes a drain pan with drain connections for vertical or horizontal <br /> operation and a horizontal auxiliary drain pan. <br /> PRODUCT SPECIFICATIONS --- SPLIT SYSTEM HEAT PUMP /COOLING COMFORTT'" COILS <br /> CASED UPFLOW/ DOWNFLOW/ HORIZONTAL <br /> 4TXCA002DS3HCA 4TXCB004DS3HCA 4TXC8006DS3HCA 4TXCC005DS3HCA 4TXCC007DS3HCA 4TXCC009DS3HCA <br /> INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN <br /> Rows/F.P.I. 2/20 3/12 3/14 3/12 3/14 3/16 <br /> Face Area(sq.ft.) 3.00 5.00 6.00 5.00 6.00 7.00 <br /> Tube Size 3/8 3I8 3/8 3/8 3/8 3/8 <br /> Refrigerant Control(No Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleetl TXV Non-Bleed TXV <br /> internal check valve) <br /> Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT <br /> Duct Connections See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing <br /> REFRIGERANT R-410A R-410A R-410A R-410A R-410A R-410A <br /> CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED BRAZED <br /> Line Size--Gas(in.) 3/4 7/8 7/8 7/8 7/8 7/8 <br /> Line Size--Liquid(in.) 3!8 3/S 3/8 3/8 3/8 3l8 <br /> DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D H X W X D H X W X D <br /> Cratetl(H x W x D) 21-3/8 x 17-1/2 x 26-1/2 26-3/8 x 20-1/2 x 26-1/2 30-5/8 x 20-1/2 x 26-1/2 26-3/8 x 24 x 26-1/2 30-5/S x 24 x 26-1/2 34-1/2 x 24 x 26-1/2 <br /> Uncrated 17-5/8 x 14-1/2 x 21-1/2 22-5/8 x 17-1/2 x 21-1l2 26-7/8 x 17-1/2 x 21-1/2 22-5/8 x 21 x 21-1/2 26-7l8 x 21 x 21-1/2 30-5/8 x 21 x 21-1/2 <br /> WEIGHT(Ibs) <br /> Shipping--Net 42/34 58/50 60/52 65/57 69/61 78/70 <br /> [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps(A.H.R.I.Standard 210/240). <br /> Refer to the Split System Outdoor product information site or www.ahrinet.org <br /> PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS <br /> AIRFLOW(CFM)VS.PRESSURE DROP <br /> PRESSURE DROP(INCHES OF WATER COLUMN) <br /> Model .05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 <br /> 4TXCA002DS3HCA 225 340 430 510 585 650 715 775 <br /> 4TXCB004DS3HCA 440 655 825 970 1100 1220 1330 1435 <br /> 4TXCB006DS3HCA 430 640 815 965 1095 1220 1335 1445 <br /> 4TXCC005DS3HCA 520 770 970 1145 1300 1440 1570 1695 <br /> 4TXCC007DS3HCA 505 760 965 1140 1300 1445 1580 1710 <br /> 4TXCC009DS3HCA 490 740 940 1120 1280 1425 1565 1695 <br /> Library Unitary <br /> Since the manufacWrer has a policy of continuous product and Product Section COI�S <br /> productdataimprov2ment,itreservestherighttochangespecifica- PfOdUCI C011 <br /> tions and design withou[notice. <br /> Model 4TXC-DS <br /> Literature Type Submittal <br /> Ingersoll Rand c �1� us Date 01/16 <br /> 6200 Troup Highway File No. 4TXC-DS-SUB-1 <br /> Tyler,TX 75707 Intertek Supersedes New <br /> ,�����p,� <br />