Laserfiche WebLink
� � i <br /> BeamChek v2014 licensed to:Design Lines, Inc. Reg#2308-64256 <br /> WHITE KITCHEN WINDOW HEADERS <br /> B-06 Prepared by:JCR Date: 2/17/16 <br /> Selection (2)2x 6 HF#2 Lu=0.0 Ft � <br /> Conditions NDS 2012 <br /> Min Bearing Area R1=4.6 inz R2=4.6 inz (1.5) DL Defl= <0.01 in. <br /> Data Beam Span 2.25 ft Reaction 1 LL 1257# Reaction 2 LL 1257# <br /> Beam Wt per ft 4.01 # Reaction 1 TL 1852# Reaction 2 TL 1852# <br /> Bm Wt Included 9# Maximum V 1852# <br /> Max Moment 1042'# Max V(Reduced) 1098# <br /> TL Max Defl L/240 TL Actual Defl L/>1000 <br /> LL Max Defl L/360 LL Actual Defl L/>1000 <br /> Attributes Section (in3 Shear inz TL Defl in LL Defl <br /> Actual 15.13 16.50 0.02 0.01 <br /> Critical 11.32 10.98 0.11 0.08 <br /> Status OK OK OK OK <br /> Ratio 75% 67% 19% 17% <br /> Fb si) Fv( si) E ( si x mil) Fc�( si) <br /> Values Reference Values 850 150 1.3 405 <br /> Ad usted Values 1105 150 1.3 405 <br /> Adjustments CF Size Factor 1.300 <br /> Cd Duration 1.00 1.00 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> CI Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform TL: 180 =A <br /> Par Unif LL Par Unif TL Start End � <br /> 40 H =50 0 2.25 <br /> 640 I =800 0 2.25 <br /> 438 J =613 0 2.25 <br /> J <br /> I <br /> H <br /> Uniform Load A <br /> 0 � <br /> R1 = 1852 R2 = 1852 <br /> SPAN=2.25 FT <br /> Uniform and partial uniform loads are Ibs per lineal ft. <br /> � `-' <br />