My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4301 HOYT AVE WESTERN WASHINGTON MEDICAL GROUP 2023-04-03
>
Address Records
>
HOYT AVE
>
4301
>
WESTERN WASHINGTON MEDICAL GROUP
>
4301 HOYT AVE WESTERN WASHINGTON MEDICAL GROUP 2023-04-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 2:36:36 PM
Creation date
1/10/2018 1:17:47 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
4301
Tenant Name
WESTERN WASHINGTON MEDICAL GROUP
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A TAM7BOC60 AIRFLOW PERFORMANCE CONSTANT CFM MODE/CONSTANT TORQUE MODE _ <br /> OUTDOOR COOLING EXTERNAL STATIC PRESSURE(Constant CFM/ConstantTorque) HEATING EXTERNAL STATIC PRESSURE <br /> AIRFLOW AIRFLOW AIRFLOW <br /> MULTIPLiER AIRFLOW pOWER 0.1 0.3 0.5 OJ �•g SETTING POWER 0.1 0.3 0.5 OJ 0.9 <br /> (TONS) SETfING <br /> 370 CFM 1316/1404 1328/1330 13Z8/1244 1320/1146 1308/1033 400 CFM 1404 1424 1426 1419 1410 <br /> CFM/ton Watts 194/201 258/234 314/260 364/276 406/280 CFM/ton Watts 205 275 337 391 440 <br /> 380 CFM 1349/1435 1360/1362 1359(1278 1352/1183 1338/1074 4].0 CFM 1437 1455 1457 1451 1441 <br /> 3.5 tons CFM/ton Watts 207/213 272/247 329/273 380/290 422/295 CFM/ton Watts 218 289 351 407 456 <br /> 390 CFM 1381/1466 1391/1394 1390/1312 1383/1220 1370/1115 420 CFM 1467 1487 1489 148Z 1474 <br /> CFM/ton Watts 220/225 286/260 344/287 396/304 439/310 CFM/ton � Watts 230 303 367 423 474 <br /> 400 CFM 1413/1496 1422/1426 1421/1346 1415/1256 1402/1154 430 CFM 1500 1516 1519 1515 1505 <br /> CFM/ton Watts 234/238 300/273 360/301 412/319 456/325 CFM/ton Watts 244 317 382 441 491 <br /> 370 CFM 1485/1583 1493/1516 1493/1441 1486/1357 1475/1263 400 CFM 1586 1600 1604 1601 1592 <br /> CFM/ton Watts 269/278 337/314 398/342 452/362 498/370 CFM/ton Watts 285 360 428 490 543 <br /> 380 CFM 1521/1618 1529/1552 1528/1479 1522/1396 1511/1305 410 CFM 1622 1636 1640 1638 1629 � <br /> CFM/ton Watts 287/295 356 J 331 418/360 474/380 520/389 CFM/ton Watts 303 379 449 512 566 <br /> 4 tons 390 CFM 1557/1654 1564/1589 1564/1516 1559/1436 1548/1347 420 CFM 1659 1672 1677 1675 1667 <br /> CFM/ton Watts 306/313 376/350 440/379 496/400 544/409 CFM/ton Watts 322 399 471 535 591 <br /> 400 CFM 1593/1689 1600/1625 1600/1554 1595/1475 1585/13B9 430 CFM 1695 1708 1713 1712 1705 <br /> CFM/ton Watts 326/332 397/369 462/399 519/420 568/430 CFM/ton Watts 342 421 493 559 616 <br /> 370t CFM 1652/1748 1659/1685 1660/1616 1655/1540 1646/1456 400 CFM 1769 1782 1789 1788 1783 <br /> CFM/ton Watts 360/365 433/403 500/433 559/454 610/465 CFM/ton Watts 385 467 543 611 671 <br /> 380 CFM 1694/1789 1701/1727 1701/1659 1697/1548 1688/1503 410 CFM 1811 1826 1831 1832 1827 <br /> 4.5 tons**t CFM/ton Watts 386/390 460/427 528/458 589/480 641/491 CFM/ton Watts 411 495 572 643 704 <br /> 390 CFM 1736/1831 1742/1770 1744/1703 1740/1629 1732/1549 420 CFM 1854 1869 1875 1877 1872 <br /> CFM/ton Watts 413/416 489/454 558/484 620/506 673/518 CFM/ton Watts 439 525 604 676 739 <br /> 400 CFM 1778/1873 1784/1813 1786/1747 1�83/1675 1776/1597 430 CFM 1898 1913 1919 1921 1918 <br /> CFM/tpn Watts 442/443 519/481 590/512 653/534 707/546 £FM/ton Watts 468 556 637 711 777 <br /> 370 CFM 1826/1921 1833/1862 1835/1797 1832/1726 1826/1650 400 CFM 1963 1978 1985 1988 1985 <br /> CFM/ton Watts 475/476 555/515 627/545 692/568 748/580 CFM/ton Watts 515 606 689 766 833 <br /> 380 - CFM 1875/1971 1882/1912 1884/1848 1882/1778 1876(1703 410 CFM 2014 2029 2037 2040 2038 <br /> 5 tons CFM/ton Watts S1�/512 593/550 667/581 733/603' 791/b16 CFM/ton Watts 554 647 733 811 880 <br /> 390 CFM 1924/2021 1932/1963 1935/1900 1933/1832 1927/1758 420 CFM 2066 2082 2090 2093 2090 <br /> CFM/ton Watts 551/550 634/588 710/619 777/641 836/654 CFM/ton Watts 595 691 779 859 928 <br /> 400 - CFM 197;5/2073 1983/20',15 1986/1953 1985/1886 1979/1814 430 CFM 2120 2136 2143 2147 2143 <br /> CFM/ton Watts �93/590 ' 678/629 755/660 824/682 884/695 - CFM/ton Watts 640 738 828 909 980 <br /> t Factory Setting . If the air handler is applied in downflow or horizontal configurations,the airflow <br /> **Not an actual OD size should not exceed 2000 CFM.Airflow above 2000 CFM could result in water blow-off. � <br /> Status LED will blink once per 100 CFM requested.In torque mode,actual airflow may be � All heating modes default to Constant CFM. <br /> lower. . Cooling airflow values are with wet coil,no filter <br /> • Torque mode will reduce airFlow when static is above approximately 0.4"watercolumn. <br /> MINIMUM HEATING AIRFLOW CFM-HEATER MATRIX <br /> BAYEVAC046K1 <br /> MODELNO. BAYEVAC04LG1 BAYEVAC08BK1 BAYEVAC106K1 gAYEVAC10LG3 BAYEVCB15LG3 BAYEVBC15BK1 BAYEVBC20BK1 BAYEVCC25BK1 <br /> BAYEVACOSBKI BAYEVACOSLGI BAYEVAC10LG1 <br /> BAYEVACOSLGI <br /> � TAM7BOC60 1063/1188 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625�a�/1813 <br /> D WITHOUT HEAT PUMP/WITH HP—SEE AIR HANDLER NAMEPLATE <br /> 0 <br /> � Note:Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number.This is not field adjustable. <br /> � �a> Heater no[qualified for 208V when installed in horizontal left pposition without Heat Pump <br /> N <br /> C <br /> W <br /> 2 <br /> T � <br /> Z ` <br /> � /� <br />
The URL can be used to link to this page
Your browser does not support the video tag.