My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4301 HOYT AVE WESTERN WASHINGTON MEDICAL GROUP 2023-04-03
>
Address Records
>
HOYT AVE
>
4301
>
WESTERN WASHINGTON MEDICAL GROUP
>
4301 HOYT AVE WESTERN WASHINGTON MEDICAL GROUP 2023-04-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 2:36:36 PM
Creation date
1/10/2018 1:17:47 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
4301
Tenant Name
WESTERN WASHINGTON MEDICAL GROUP
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , • • <br /> � TRANE� <br /> Product Specifications <br /> OUTDOOR UNIT(a)(b) 4TWA7060A3000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner <br /> POWER CONNS.—V/PH/HZ(�l 208/230/3/60 Equipment certification program,which is based on AHRI standard <br /> 210/240. <br /> MIN.BRCH.CIR.AMPACITY 22 �e� Rated in accordance with AHRI standard 270. <br /> BR.CIR.PROT.RTG.—MAX.(AMPS) 35 ��> Calculated in accordance with Natl.Elec.Codes.Use only HACR <br /> circuit breakers or fuses. <br /> COMPRESSOR CLIMATUFFO-SCROLL cd� This value shown for compressor RLA on the unit nameplate and on <br /> NO.USED—NO.STAGES 1—Z this specification sheet is used to compute minimum branch circuit <br /> ampacity and max.fuse size.The value shown is the branch circuit <br /> VOLTS/PH/HZ 208/230/3/60 selection current. <br /> R.L AMPS�d�—L.R.AMPS 16.2—110 �e� No means no start components.Yes means quick start kit <br /> components.PTC means positive temperature coefficient starter. <br /> FACTORY INSTALLED Optional kit shown. <br /> (f) Standard Air—Dry Coil—Outdoor <br /> START COMPONENTS�e� NO(Uses BAYKSKT263) �g� This value approximate.For more precise value see unit nameplate. <br /> INSULATION/SOUND BLANKET NO �h> Reference the outdoor unit ship-with literature for refrigerant piping <br /> COMPRESSOR HEAT YES length and lift guidelines.Reference the refrigerant piping software <br /> pub#32-3312-xx or refrigerant piping application guide SS- <br /> OUTDOOR FAN PROPELLER APG006-xx for long line sets or specialty applications(xx denotes <br /> latest revision). <br /> DIA.(IN.)—NO.USED 27.6—1 (�) Trane outdoor condensing units are factory charged with the system <br /> TYPE DRIVE—NO.SPEEUS DIRECT—1 charge required for the outdoorcondensing unit and 15 feet of tested <br /> connecting lines.If connecting line length exceeds 15 feet,then final <br /> CFM @ 0.0 IN.W.G.�f� 4760 refrigerant charge adjustment is necessary.Each additional foot over <br /> NO.MOTORS—HP 1—1/4 15 feet requires 0.6 ozs of refrigerant.See the Installer's Guide for <br /> full charging instructions. <br /> MOTOR SPEED R.P.M. 825 <br /> VOLTS/PH/HZ 208/230/3/60 <br /> F.L.AMPS 1.3 <br /> OUTDOOR COIL—'TYP� SPINE FIN'"' <br /> ROWS—F.P.I. 2-24 <br /> FACE AREA(SQ.FT.) 29.15 <br /> TUBE SIZE(IN.) 3/8 <br /> REFRIGERANT CONTROL EEV <br /> REFRIGERANT <br /> LBS.—R-410A(O.D.UNIT)(e) 13 LBS.,3 OZ <br /> FACTORY SUPPLIED YES <br /> LINE SIZE—IN.O.D.GAS�h���� 1 1/8 <br /> LINE SIZE—IN.O.D.LIQ. 3/8 <br /> CHARGING SPECIFICA,TIONS <br /> SUBCOOLING 10°F <br /> DIMENSIONS H X W X D <br /> CRATED(IN.) 51 x 38.7 x 35.1 <br /> WEIGHT <br /> SHIPPING(LBS.) 330 <br /> NET(LBS.) 293 <br /> q 4TWA7060A-S U B-3 B-E N <br /> � 1�0� �� --�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.