i __.__ -- <br /> ' <br /> i <br /> SITE PLAN NOTES <br /> Any grading/fill on this site shall be done so as to not impact the surrounding properties, Fire alarm systems shall be installed according to NFPA Chapter 72,2010 Edition. <br /> and shall follow Washington State Best Management practices for erosion control, Installation of fire alarm components,including basic wiring,may not commence <br /> including drain boots on drains and silt fencing. before plans are approved by the Fire Department Plan Reviewer. Fire alarm <br /> drawings must be professionally rendered,in sufficient detail,and must be internally <br /> No additional impervious area will be created in the State Street right-of way as the consistent.Riser diagrams must match installation plans and load calculations. <br /> result of this project. Components must be listed and approved for use together.Changes to plans must <br /> include new drawings and calculations and must be approved by the Fire Department I <br /> Parking on the Right of Way will be addressed under separate permit(Application Plan Reviewer prior to installation. <br /> Pending) <br /> Fire alarm installation is subject to field inspection by a Fire Department Inspector. <br /> A reduced pressure backFlow assembly will be installed as backflow prevention the An approved set of plans and the Engineering&Public Services Department <br /> existing water supply line. electrical permit must be present for any installation inspection. Fire alarm systems <br /> shall be installed under permit of the City of Everett Engineering&Public Services <br /> The landscape areas adjacent to the gate shall be planted with a minimum of four 2 Department.Electrical inspections and approval are required prior to calling for <br /> 1/2a€caliper trees or six-foot tall spreading evergreen trees with 30 shrubs and acceptance tests. <br /> groundcover. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final <br /> Knox Boxes and Keys wili be installed in accordance with requirements of the occupancy(NFPA 72,2010 Edition,Chapter 10, page 114). <br /> Everett Fire Department. <br /> A gas detection system will also be required for the type of gas used in the extraction <br /> Portable fire extinguishers with a minimum U.L.rating of 2-A:10-B:C will be provided process. <br /> within 75 feet of travel on all floors of each building during construction and prior to <br /> occupancy. All fire alarm control panels(FACP)and sprinkler valves shall be in heated rooms or <br /> closets with standard man door access.Locations shall be approved by the Fire Code <br /> An approved automatic fire detection system shall be provided shall be nstalled in Official(NFPA 13 8.16.4.1.3). <br /> accordance with City Ordinance No.3021-07,Chapter 16.76,of the Ev�.:rett Municipal <br /> Code. Plans for such system shail be submitted to the Fire Code Official for review and All occupants shall meet State requirements for marijuana processing or extraction <br /> approval prior to installation.Submittal shail include cut sheets of all eq��ipment facilities specifically WAC 51-54A-0105 and WAC 51-54A-3800 All Occupants shail <br /> intended for use. comply with Ordinance 3407-14 and all requirements of state law,the Washington <br /> State Liquor and Cannabis Board,and the City. <br /> Appropriate trip tests,witnessed by a Fire Department Inspector,shall t:e performed, <br /> along with a certificate of completion, prior to final acceptance of the system. <br /> F�ctraction operations within the building shall apply separately for permits based on <br /> City and State Requirements,and shall be subject to the approval of the Everett Fire <br /> Department. <br /> Marijuana producers and processors are required to acquire all necessary business <br /> licenses and are required to comply with municipal tax regulations. <br /> No. Description Date � j <br /> Riverside Lofts 1 Revision 1 oate,_ Site Plan Notes � <br /> � <br /> SC�S AC�CI IILPCL Projectnumber 2015=01 � <br /> __ _ Date Sept 28,2015 2 of 2 � <br /> Tenant Improvement � <br /> Scott G Schreffler, RA Drawn by A�tnor _____ N <br /> Checked by Checker Scale N ; <br /> rn <br />