Laserfiche WebLink
, <br /> • GENERAL � • YES <br />• ` Bathroom doors are easily and quick(y openable from the outside when locked [� ❑ <br /> Carbon Monoxide alarms are installed as required in R315,1 on each level of the home. �j <br /> Srrtoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outslde each separate <br /> �` sfeeping area in the immediate vicinity of sleeping rooms(R314j. � <br /> 5moke and Carbon Monoxide alarms are Installed in such a manner so that the audible warning may be heard in all � � <br /> parts of the dwelling upon activation of a single device, <br /> Access road and water supply meet local�re jurisdicttonal requirements. � <br /> R325.4 Operable parts of door handles,puils,latches,locks and other devices installed in AFH shail be operabie with one hand <br /> and shall not requfre tlght grasp(ng, inching or twistin of fihe wrist(lever-t pe). � <br /> Pocket doors shall have graspaBle hardware avaflabte when In the closed or open position. � <br /> R311.8 Ramps � �:f�' ' � � ' ' � YES NO <br /> tns►de Rarimp. N/A ' [] Q <br /> R311.8.1 Maximum Slope one unit verticai in twefve units hortzontai(8.3%siope. Exception R311.8.1 Not ailowed in AFH <br /> R311.8.2 Landing Requirements;mtn.3X3 foot landing at top/6ottom,where doors apen onto ramps,and where ramp changes . <br /> directions. 0 0 <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311,8.3,3. <br /> OutsJde Ramp N/q� ' • � • . YES iV0 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(B.3%siope).(Exception R311.8.1 Not ailowed in AFH) ❑ <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at topJbottom,where doors open onto ramps,and where ramp changes <br /> dfre�tlons. <br /> R325,9.1 Handrails requlred on both sides of ramp in accordance wlth R311.8.3.1—R311.8.3,3. [� <br /> Guards below are depicted vertically as an example only.Ali Ramps must have Guards � ❑ <br /> ^"" Handrafl both sides <br /> less than 4" 34"-38" <br /> � <br /> G ua rd <br /> 36"min <br /> � 3'x3'min <br /> Ianding <br /> 3'x 3'min <br /> landi�g <br /> 3' One unit vertical in iweive units horizontal �_g��� <br /> mInlmum 1s an 8.395 slope all along surface of the ramp. minimum <br /> R3i1.2 Means of Egress • YES O <br /> R311.2 Door must be side-hinged wfth min.widtt�of 32 inches between face of door and stop.Hei ht not less than 78 inches. <br /> R325.4 Operable parts of door handles,pu1ls,laYches,tocks and other devices installed in AFH shaii be operabte with one hand <br /> and shall not require tight grasping,pinching or tvrtsting of the wrist(leve�- pe}. ❑ <br /> R325,4 Required exit door hardware shall unloek Inside and outside mechanisms when exitingthe building aliowing re-entry 0 <br /> wfthout use of key,toof or s ecial,kAowled e. Required exif door shaf(have rto additionat locking devices, . <br /> R311.7 Stairways N/A � � � YES NO <br /> R311.7.4.1 Rlser Helght:Max riser height shall be 7'/< inches(8 lnches In structures built prior to July 1,2D04) <br /> R311.7.4,2 Tread Depth:Min.tread depth shall be fn 10 inches 9 lnches in structures built prior to July 1,2004) � <br /> R325.10.2 Handrails for Treads end Risers shall be installed on both sides oftreads and risers numbering from one riser to muf#iple � � <br /> risers.Handrails shall be)nstalled ln accordance with R311.7.7.1—R311.7,7.4 <br /> �-. <br /> Effective:2013 July 01 <br /> Updated:2013 June <br /> s��� <br /> �__._.:_-� <br />