: • • � ' � • • <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Amazon Delivery Station DSE4 Date 05/11/2017 <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br /> Energy Code,Commercial Provisions. <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> SCOPE <br /> Low energy spaces are identified on plans;include project information, <br /> C402.1.1 Low energy spaces and calculations if applicable,that demonstrate spaces are eligible for <br /> envelope provisions exemption <br /> Semi-heated spaces are identified on plans,include calculations that <br /> C402.1.1.1 Semi-heated spaces demonstrate spaces are eligible for wall insulation exemption <br /> Provide building area,average wall and roof U-factor,and installed <br /> C402.1.2 Equipment Buildings equipment information that demonstrates equipment building is eligible for <br /> envelope provision exemption <br /> Walk-in and Cooler and freezer spaces are identified on plans;C410 envelope <br /> C410.2 warehouse cooler compliance forms provided(pending) <br /> and freezer spaces <br /> C101.4.1 Mixed occupancy Spaces with different occupancy requirements are identified on plans <br /> Existing unconditioned spaces changing to semi-heated or conditioned <br /> C5032 Change of space space,and existing semi-heated spaces changing to conditioned space, <br /> conditioning are identified on plans.Include calculations that demonstrate baseline and <br /> final level of conditioning. <br /> Existing F,S and U-occupancy spaces undergoing a change in occupancy <br /> are indicated on plans;include calculations that demonstrate upgrade . <br /> complies with the current WSEC. <br /> Change of Pre-2002 Group R spaces undergoing a change to a commercial <br /> C505.1 occupancy are indicated on plans;include calculations that demonstrate <br /> occupancy <br /> upgrade complies with the current WSEC. <br /> Non-Group R occupancy spaces undergoing a change to Group R are <br /> indicated on plans:include calculations that demonstrate upgrade <br /> complies with the current WSEC. <br /> ENVELOPE PROVISIONS <br /> Indicate envelope insulation compliance path and provide applicable <br /> forms;ENV-PRESCRIPTIVE or ENV-UA/ENV-SHGC for component <br /> C103.2 Compliance Performance <br /> C103.6.3 documentation <br /> If complying via total buidling performance,provide a list of all proposed <br /> envelope component types,areas and U-values <br /> C303.1.1 Insulation Indicate identification mark shall be applied to all insulation materials and <br /> C303.1.2 identification insulation installed such that the mark is readily observable during <br /> inspection <br /> C303.1.3 Fenestration product Fenestration products shall be labeled with rated U-factor,SHGC,VT,and <br /> C402.4.3 rating leakage rating <br /> Indicate installation methods,thicknesses,densities and clearances to <br /> C303.1.1 General insulation achieve the intended R-value of all insulation materials: <br /> C402.2.1 installation Where two or more layers of rigid insulation will be used,indicate that <br /> edge joints between layers are staggered <br /> Indicate R-value(s)of cavity/continuous insulation on roof sections; <br /> Indicate framing materials on roof sections; <br /> Indicate method of framing for ceilings below vented attics and vaulted <br /> ceilings per A1022(std,adv); <br /> C103.2 Roof assembly Provide area weighted average U-factor calculation for insulation whose <br /> C402.22 insulation thickness varies by 1 inch or less; <br /> Indicate effective U-factors of tapered insulation entirely above deck per <br /> A102.2.6;include roof configuration and slope,maximum R-value at peak <br /> and minimum R-value at low point for all roof surfaces <br /> Indicate R-values for thermal spacers and each insulation layer,and liner <br /> system(LS)method for metal building roofs <br /> C402.2.2 Skylight curb Indicate curb insulation R-value on roof section if not included in skylight <br /> insulation NFRC rating <br /> Indicate R-value(s)of cavitylcontinuous insulation on wall sections; <br /> Indicate framing materials on wall sections; <br /> Indicate method of framing for wood const per A1032(std,int,adv); <br /> C103.2 Indicate material density category,wall weight and heat capacity for <br /> C402.2.3 Above/below grade qualifying mass walls; <br /> C4022.4 wall insulation <br /> C303.2.1 For qualifying ASTM C90 masonry walls,indicate loose-fill core insulation <br /> material and percentage of cores filled including grouted cores,bond <br /> beams,vertical fills,headers and any other grouted cores; <br /> Indicate method of protection of exposed exterior basemenUcrawlspace f� <br /> wall insulation , 'F�� � <br /> t , <br /> �, . <br />