Laserfiche WebLink
� � <br /> ENG/NEER/NG <br /> ` �::�:���:=��: ' � PUBL/C SERV/CES DEPARTMENT <br /> March 15, 2017 <br /> Dustin Thorlakson <br /> dthorlakson@fhoarch.com <br /> Freiheit & Ho Architects, Inc. P.S. <br /> 5209 Lake Washington Blvd NE <br /> Kirkland, WA 98033 <br /> RE: Owner: Amazon Corporate, LLC <br /> Job Address: 6611 Associated Blvd. <br /> Plan Check Number: M1703-020 <br /> Dear Mr. Thorlakson, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. These comments address building issues only. Additional <br /> revisions or additions may be required by other departments (such as Building Architectural, Public <br /> Works, Planning, or Fire). All references refer to the 2015 International Building Code (IBC), the <br /> 2015 International Existing Building Code (IEBC), the 2015 International Property Maintenance <br /> Code (IPMC), the 2015 International Fire Code (IFC), the 2015 International Mechanical Code <br /> (IMC), and the 2015 International Energy Conservation (IECC), as amended by the State of <br /> Washington (WSEC) and adopted by the City of Everett. The current IBC referenced standard for <br /> accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI A117.1). <br /> Federal ADA, FHA, and HUD regulations and standards, including the Fair Housing Accessibility <br /> Guidelines may be more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of construction documents <br /> and/or calculations stamped &signed reflecting the corrections requested. All <br /> revisions require the person delivering the drawings to replace the revisions into the <br /> two sets here at our offices. For significant revisions, or if the revisions are coming <br /> directly from a document printing facility, please make arrangements with them to <br /> print and deliver two replacement sets. <br /> Structural <br /> 1. On Sheet M1.2, between Grids D/E and Grids 3/4, Grids 5/6, there appears to be two <br /> HVAC mechanical units that weigh 3500 Ibs in each location. Please provide <br /> engineering calculations and details indicating that the units are properly anchored per <br /> ASCE 7-10 Sections 13.4 and 13.6, based on the governing design lateral force. Also, <br /> please provide calculations and details indicating the new units are adequately <br /> supported by the existing framing or that strengthening of existing members is <br /> provided per IEBC Section 707.2. <br /> Page 1 of 2 � <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257-8857 <br />