Laserfiche WebLink
. • • <br /> 4. The existing window adjacent the added stairs will get replaced <br /> with the required tempered safety glass as noted on S2 <br /> 7. Closed cell spray foam has an aged R-value of 6.0 per inch thus <br /> requiring 3.5 in. min. thickness to obtain R-21 insulation value <br /> 8. The gap will be 1/2 in. its purpose is to provide an insulated <br /> thermal break from the foundation <br /> 9. I have added fire blocking details to the drawings on S5 & S7 <br /> 10. please see added details on S5 <br /> 11. please see added details on S2 <br /> 12. The rake wall under stringer is the furred wall detailed on S5 <br /> 13. please see drawing on S7 <br /> 15. There will be 1.5 in. XPS foam under the slab and the 1.5 in. <br /> XPS foam on top of slab with nailers and 3/4 in. plywood subfloor <br /> completing the thermal break as detailed on S5 <br /> 18. please see detail on S6, also I will replace all existing smoke <br /> detectors with new combination smoke/CO. alarms which <br /> includes the main living area, all bedrooms and the hall outside <br /> the bedrooms <br /> 19. please see detail on S5 <br /> Please call me if you have any questions. <br /> ph.# 425-423-0246 hm. 425-359-8570 cell. <br /> Thank you, <br /> �� <br /> Dennis Colyn <br /> 2 <br />