Laserfiche WebLink
' • • <br /> I - h i <br /> 4�.�._....,...,: 2..�..,.....�'"7� <br /> ""'•"........."".' <br /> a. Added rest of statement for 5a to sheet. <br /> 3. Exterior walls located less than 5 feet from the <br /> property line are required to be one-hour fire- <br /> resistance rated tested in accordance with ASTM E 119 <br /> or UL 263, with exposure from both sides. Provide <br /> detail of approved assembly including assembly <br /> number. <br /> a. <br /> eathing on exterior 5/8" drywall on inside of <br /> � n�. , _ - _ <br /> 4. Specify minimum egress requirements for new <br /> Bedroom 3. <br /> a. _ <br /> 5. Gas water heater is not allowed to be accessed from <br /> the bedroom. <br /> a. <br /> 6. Specify water heater requirements for seismic bracing. <br /> a. <br /> 7. Specify insulation requirements for all wall, floor and <br /> ceiling assemblies in area being converted into living <br /> space per 2012 Washington State Energy Code. <br /> a. _ . _ �, .._,__. -, - :� need for <br /> �1, R-38-49 in ceiling. <br /> ThankYou <br /> Gregory Wolfkill <br /> � <br />