Laserfiche WebLink
� , . <br /> A & E Insula�ion, Inc. <br /> ' 15205 39th Avenue NE <br /> Marysville, WA 98271 <br /> Office: (360) 651-1058 Fax: (360) 651-1259 <br /> Website: tivv��v+l.�ei��si.�latiar�.c�m <br /> .__..__�_.______�_�____ Date: 8/24/17 <br /> Builder or Owner Signature Homes <br /> House address or lot #: 4125 Grand Avenue, Everett, WA 98203 <br /> Ring (if applicable): Open ��A;% B <br /> Air Leakage Testing (Biower poor Test) <br /> Conditioned Floor Area: '2 %7 � Calculated Volume (Cubic Feet) <br /> --� <br /> �_ Ce�ling Height (ft) �;,,�<�S ' � `�-1��; <br /> Standard Tested CFM50 Test Result (ACHSo) <br /> _ , , <br /> <5.0 ACHSo ' � � <br /> ((CFM;�X 60)/Conditioned Volume) � , � � Z � � �j <br /> M � <br /> : <br /> �� ----- —� <br /> Si�nature_ ,i-�-z `�;i'=�- -�.r_. <br /> �lclssary <br /> 6��scal (�a); Unit of pressure <br /> L.ri�: C.Oi'iK;ttilc7f9�'i3 i E�iar a,�a ir. Sy�c�Cp f��� <br /> CfiMso: Cubic feet per minute of air leakage at 5� p�scal:= of�ressure <br /> To$a� �.eakage: Aggregation of the entir� systems d��ct leakage in a duc�test. <br /> �o��itioned Volume: Volume of conditio�ed space (CFA X ceiling hieght) <br /> �t��5�: Air �hanges per hour at 50 pascals of pressure <br /> Air Leakage Testi�g Code !anguage <br /> ���0"1.4.1.2 Testing.The building or dwelling unit shail �e iested and verifi�d as having an air leakage rate of not <br /> �xce�ding 5 air changes per hour.Testing shal! be c�rnducted with � bl�,nrer duor at a pressure of 0.2 inches w.�. <br /> �5+��aGcals). Where required by the code official, testing shrr!:bz c�ra�l�c�ed by an approved third party.A written <br /> repori�of the results of the test shall be signed by tne part�ca:�d�rczing tne test and provided to the code official. <br /> Testing shalf be performed at any time after creat.��n e���l1�aenei.���ior�s�f the building thermal envelope. Once <br /> visunJ inspection has confirmed sealing (see Ttrbde R�t72.4.1.�J,. o,�e:�rr�bl€� windows an�!doors manufactured by sma{l <br /> �usfriess s,�all be permitted to be sealed off r�� the j�r�arr►�prior to th2 test. During resting: <br /> L. Exierior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyonci the intended <br /> wratherstripping or other infiltration contrc�l �r�easui-es; <br /> 2. DarYipers including exhaust, intake, mar;eup air, �ar.k�Jrafc anc! flue dampers shall be closed, but not sealed beyond <br /> in;ended infiltration control measures; <br /> :3. Interior doors, if installed at the time of tne test, sha�l be open, a�cess hatches to conditioned crawl spaces and <br /> cc,r�ditioned attics shal! be open; <br /> 4. Exterior o�enings for r_o;�tinuaus veniilation systems and F�eat re:.ovey y venr.iiators s`r�all be,:.losed and sealed; <br /> 5. I-leating and cooling systeRis, if installed at the ill?�C' C)�tfl?test, s���ali be turned off; and <br /> �� S�.ipply and return registers, 'if ire�tal�ea at tN�e tii7�e �+�;iF�t�st, shall �e fu!ly �pen. <br /> f IVAC ducts supply and return registers shail ncr; b:: s,.:�:l�.�ci. <br /> � � <br /> . . , ._ .,., .. ..-�: . .. <br />