My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4006 HIGH ST 2018-01-18
>
Address Records
>
HIGH ST
>
4006
>
4006 HIGH ST 2018-01-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2018 9:50:10 AM
Creation date
1/18/2018 9:49:59 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGH ST
Street Number
4006
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� • <br /> PUBL/C L�t/OR/C5" <br /> November 17, 2015 <br /> CRMA Investments <br /> PO Box 5222 <br /> Lacey WA 98509 <br /> Subject: Project: CRMA <br /> Job Address: 4006 High St <br /> Plan Check No: C1507-008 <br /> Dear Sirs: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2012 International Building Code,) (2012 International Residentiai Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2012 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it wili be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested. <br /> 1. Please see the previous correction letter (enclosed), all items that are highlighted need to <br /> be addressed alonc� with the following c�rrecti�ns for the revised plans s�ibmitted. <br /> 2. The 2 x 8 Hem Fir #2 and the 2 x 6 Hem fir #2 "Rim Joists"specified for deck beams <br /> appear to be undersized for t the required design loads. Provide gravity calculations for <br /> beams supporting the decks. <br /> 3. Provide gravity calculations for diagonal (2) 2 x 8 beam supporting deck joists at <br /> southwest corner of proposed deck. <br /> 4. Attic insulation is required to be minimum R-49. The insulation can be reduced to R-38 <br /> "wherever the full height of R-38 insulation extends over the wall top plates." A 2 x 6 <br /> rafter does not provide the full height required for R-38 insulation without compression. <br /> 5. R-10 Rigid insulation is required at all new headers. Show insulation required in section <br /> view. <br /> ENGIN����,����I�I����/i��a�����l�14�i7-�' Q46�4�h��j��• Everett,WA 98201 •(425)257-8800• Fax(425)257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.