f , . <br /> Simple Heating System Size: Washington State <br /> This heatinp svstem sizinq calculator is based on the Prescriptive Requirements of the 2012 Washinqton State Enerqv Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heatinq loads only.ACCA procedures for sizinq coolinq svstems should be used to determine coolina <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact lnformation <br /> Unit E1 Townhome Polygon Northwest <br /> Eclipse Jamie Aubrey <br /> Everett,Washington (425)586-7700 <br /> H@eYlllq SVSY@Ill TVpB: �O Forced Air Furnace Q Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Desiqn Temperature <br /> i"`;�""t","'. I Design Temperature Difference(�T) 47 <br /> . [verett J� �J pT=Indoor(70 degrees)-Oufdoor Design Temp <br /> a�� <br /> Area of Buildinq <br /> Conditioned Floor Area <br /> �"��''"`=�'°"` Conditioned Floor Area(sq ft) 1,344 <br /> Average Ceiling Height Conditioned Volume <br /> �"`.""�"O1: Average Ceiling Height(ft) 8.5 11,424 <br /> Glazinq and Doors U-Factor X Area = UA <br /> �n"irii�tion`. 0.30 183 54.78 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> �nstructions R 49 ��-- � i 0.026 591 15.37 <br /> , <br /> E ��,_,��- <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> i�,,i��,�uo��,. � 0 <br /> � No Vaulted Ceilings in this proje t � ,� --- <br /> �.. . ,w„� . , <br /> Above Grade Walls�SeeF;y�.e�� U-Factor Area UA <br /> Insiiuctions i 0.056 413 23.13 <br /> rtzi .p. I <br /> Floors U-Factor Area UA <br /> Instructions � � �� "°° ��� 0.029 345 10.01 <br /> R 30 � <br /> BQIOW G�BCIC WBIIS(see Figure 1) U-Factor Area UA <br /> li�structions ' � � <br /> No flelow Giade Walls in this piojed. � --- <br /> Slab BelOw Grade(see Figure�) F-Factor Length UA <br /> Instnictionr, � <br /> , No Slab Below Grzde in this project. ���_ --- <br /> Slab on Grade�see Fry�re�� F-Factor Length UA <br /> Inr:[ructions -""" 0.540 34 18.36 <br /> R 10 Perimeter � I <br /> s <br /> Location of Ducts <br /> Instructions --- <br /> •�------ � Duct Leakage Coefficient <br /> i Condrtioned Space � <br /> 1.00 <br /> Sum of UA 121.64 <br /> Envelope Heat Load 5,717 Btu/Hour <br /> Flqufe 1. SumofUAX:�T <br /> Air Leakage Heat Load 5,799 Btu/Hour <br /> VolumeX D.6X4TX.018 <br /> AhoveGrade Building Design Heat Load 11,516 Btu/Hour <br /> � � � Air Leakage+6rvelope Neat Loss <br /> ���--�~ �' ' Building and Duct Heat Load 11,516 Btu/Hour <br /> Ducts in unconditioned space:Sum o/Building Hea(Loss X 1.10 <br /> Ducts in conditioned space:Sum ol8uilding Heaf Loss X 1 <br /> Maximum Heat Equipment Output 16,122 Btu/Hour <br /> Building and Ducf Heat Loss X 1.40/or Forced Air Furnace <br /> Bw7ding and Duct Heat Loss X 125 lor Heaf Pump <br /> : � ' � <br /> � (07/01/13J <br />