Simple Heating System Size: Washington State <br /> This heatinq svstem sizinq calculator is based on the Prescriptive Requirements of the 2012 Washinqton State Enerqv Code(WSEC)and ACCA <br /> Manuals J and S This calculator wilf calculate heatinq loads onlv ACCA qrocedures for sizinq coolinq svstems should be used to determine coolinq <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values wiil be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit E1 Townhome Polygon Northwest <br /> Eclipse lamie Aubrey <br /> Everett,Washington (425)586-7700 <br /> Heatinq System Tvpe: OO Fo«e�n��F���a�e Q Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"lnstructions". <br /> Desiqn Temperature <br /> instru�t�o�,s ___.___..__,.._.:._.,...;:�..._..,..._....._....,:......_..............._ Design Temperature Difference(�T) 47 <br /> ��Everett 1C ��-� � pT=Indoor(70 degrees)-Outdoo�Design Temp <br /> �L'__ <br /> � <br /> Area of Buildinq <br /> Conditioned Floor Area <br /> mst�uceon5 Conditioned Floor Area(sq ft) �,3� <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 11,424 <br /> Glazin4 and Doors U-Factor X Area = UA <br /> Instructions 0.30 183 54.78 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions R A� "'' �I� 0.026 591 15.37 <br /> l ..__ _ —.. _ ,_ <br /> Single Rafter or Joist Vaulted C gilings `, ^�� _ U-Factor Area UA <br /> Instruc[ions - P '— �'� --- � <br /> N� o V a u l t e d Ceilin s in this m ec[ I <br /> Above Grade Walls�5ee Fry�.e�1 � U-Factor Area UA <br /> __ <br /> Instructions i — "`�— -�_"� _�I I 0.056 413 23.13 <br /> R-21 � <br /> � —____ ___ ._..,.. <br /> Floors U-Factor Area UA <br /> Instructions I "' �`- � � 0.029 345 10.01 <br /> I I R-30 <br /> l <br /> Below Grade Walls�SeeF�y�.e�J U-Factor Area UA <br /> InsVuctions "�- �� "' � --- <br /> No Beloev Grade Walls in this pro)ect j.� <br /> i _.. ..._.. ..__ .:_ ' <br /> � <br /> Slab Below Grade�5 <br /> �eF;g,,.ef� F-Factor Length UA <br /> Instructions ....... .___ __ _.:. _� � � <br /> I No Slab 8elow Grade in this pro�ect <br /> � --- <br /> � i..__. ..__.. ._..— -- <br /> Slab on Grade�see Fry�.e�1 F-Factor Length UA <br /> Instructions " � l 0.540 34 18.36 <br /> � I R-10 Pernneter � <br /> ` ......._ _.-- TT i, —. <br /> Location of Ducts <br /> instructions ; _:.._._....__=.P--.-..._._.__`.._...____�:_:_-......-- 1 Duct Leakage Coefficient <br /> I �Condicioned 5 ace �� J 1.00 <br /> Sum of UA 121.64 <br /> Envelope Heat Load 5,717 Btu/Hour <br /> FlqlJf@ 1. SumofUAXOT <br /> � Air Leakage Heat Load 5,799 Btu/Hour <br /> VolumeX O.6XOTX.018 <br /> AhoveGrade Building Design Heat Load 11,516 etu/Hour <br /> '�,.� Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 11,516 Btu/Hour <br /> - Ducfs in unconddioned space:Sum of Building Heaf Loss X 1.10 <br /> Ducts in conditioned space.'Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 16,122 Btu/Hour <br /> Building and Duct Heat Loss X 1.40(or Forcod Ai�Furnace <br /> Building and Duct Heal Loss X 1.25 for Heaf Pump <br /> (07/Ol/13) . 1 <br /> f, : ; <br />