Laserfiche WebLink
• • <br /> 9. The "N" Office does not meet the minimum requirement for a habitable room per section R304 <br /> IRC. <br /> a. See sheet A2.3(N)office is now(N)storage <br /> 10. Provide R-10 rigid insulation at all headers in walls per Table R402.1.1 of the WSEC. <br /> a. See sheet A4.1,Section A <br /> 11. Provide ledger details and section. Ledger bolts shall be staggered top and bottom. <br /> a. See structural engineer response letter <br /> 12. Specify Lateral connection per Section R507.2.4 IRC. Show connection on section and in plan <br /> view. <br /> a. See structural engineer response letter <br /> 13. Specify post/footing connection of all new decks capable of resisting uplift and lateral <br /> displacement per engineered design. <br /> a. See structural engineer response letter <br /> 14. Provide detail for the construction of the roof at the garage level. Specify how roof structure is <br /> attached to the exterior wall and how it is capable of supporting the code required loads. <br /> a. See structural engineer response letter <br /> 15. Below grade walls are required to be insulated on the interior per table R402.1.1 WSEC. Provide <br /> detail of insulation at interior below grade walls; include fire blocking location and <br /> requirements. <br /> a. See sheet A2.1 and sheet A4.1,Section C <br /> 16. Provide minimum 50 CFM exhaust fan in bathroom and laundry room. Exhaust fans shall be <br /> vented to the exterior of the building. <br /> a. See sheet A2.1 <br /> I trust that this is the information that you require for the continuation of this application. If you require <br /> anything further, please do not hesitate to contact me at the number listed below. <br /> Sincerely, <br /> Tom Rochon <br /> Project Architect <br /> Designs Northwest Architects <br /> TR/Ih <br /> Enclosures <br /> Tel 360.629.3441 I Fax 360.629.6159 f1 <br /> P.O. Box 1270 110031 SR 532,Suite B I Stanwood,WA 98292 / <br /> E 1 <br /> DesignsNW.com (((,,������ r" <br />