My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3433 TULALIP AVE 2018-02-09
>
Address Records
>
TULALIP AVE
>
3433
>
3433 TULALIP AVE 2018-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2018 2:28:46 PM
Creation date
2/9/2018 2:28:30 PM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3433
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Use menu item Settings>Printing&Title Block Title GOODMAN/CHACON Page: 1 <br /> to set these five lines of information Job# 7858 : Dsgnr: CHRIS Date: 19 JAN 2017 <br /> for your program. Description.... <br /> This Wall in File:C:\Users\Chris\Desktop\retain pro.RPX <br /> License <br /> (c)W 1987-2015, Build 11.15.12.22 Cantilevered Retaining Wall Code: IBC 2012,ACI318-11,AC1530-11 <br /> License:KW-06060593 <br /> License To:STRUCTURAL DESIGN ASSOCIATES <br /> ' <br /> Criteria q Soil Data <br /> Retained Height = 3.50 ft Allow Soil Bearing = 1,500.0 psf ; <br /> Equivalent Fluid Pressure Method <br /> Wall height above soil = 0.50 ft Active Heel Pressure = 35.0 psf/ft <br /> Slope Behind Wall = 0.00 = <br /> Height of Soil over Toe = 6.00 in Passive Pressure = 250.0 psf/ft <br /> Water height over heel = 0.0 ft Soil Density, Heel = 110.00 pcf <br /> Soil Density,Toe = 0.00 pcf «4 <. , <br /> Soil Friction = 0.400 E `'' <br /> Footingll ,....<.• <br /> Soil height to ignore 1• • J <br /> for passive pressure = 0.00 in <br /> Surcharge Loads Lateral Load Applied to Stem 1 La,ljacent Footing Load Nii <br /> Surcharge Over Heel = 100.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load _ 0.0 lbs <br /> Used To Resist Sliding&Overturning .,.Height to Top = 0.00 ft Footing Width 0.00 ft <br /> Surcharge Over Toe = 0.0 .,.Height to Bottom = 0.00 ft Eccentricity = 0.00 in <br /> Used for Sliding&OverturningLoad Type = Wind(W) Wall to Ftg CL Dist = 0.00 ft <br /> Axial Load Applied to Stem Footing Type Line Load(Service Level) Base Above/Below Soil <br /> Axial Dead Load = 200.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall 0.0 ft <br /> Axial Live Load = 400.0 lbs (Service Level) Poisson's Ratio = 0.300 <br /> Axial Load Eccentricity = 0.0 in <br /> Design Summary Stem Construction li Bottom <br /> Stem OK <br /> Wall Stability Ratios Design Height Above Ftg ft= 0.00 <br /> Overturning = 2.07 OK Wall Material Above"Ht" = Concrete <br /> Sliding = 1.37 Ratio< 1.5! Design Method = LRFD ' LRFD LRFD <br /> Thickness = 8.00 <br /> Total Bearing Load = 1,443 lbs Rebar Size = # 4 <br /> ...resultant ecc. = 1.33 in Rebar Spacing = 12.00 <br /> Rebar Placed at = Edge <br /> Soil Pressure @ Toe = 831 psf OK Design Data - - -- <br /> Soil Pressure @ Heel = 452 psf OK fb/FB+fa/Fa = 0.190 <br /> Allowable = 1,500 psf Total Force @ Section <br /> Soil Pressure Less Than Allowable Service Level lbs= <br /> ACI Factored @ Toe = 1,089 psf Strength Level lbs= 521.2 <br /> ACI Factored @ Heel = 592 psf <br /> Moment....Actual <br /> Footing Shear @ Toe = 7.0 psi OK Service Level ft-#_ <br /> Footing Shear @ Heel = 0.5 psi OK Strength Level ft-#= 712.0 <br /> Allowable = 75.0 psi <br /> Moment Allowable = 3,739.3 <br /> Sliding Calcs Shear Actual <br /> Lateral Sliding Force = 466.5 lbs <br /> less 100%Passive Force= - 222.2 lbs Service Level psi= <br /> less 100%Friction Force = - 417.2 lbs Strength Level psi= 6.9 <br /> L Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 222.5 <br /> ....for 1.5 Stability = 60.3 lbs NG Wall Weight psf= 100.0 <br /> Rebar Depth 'd' in= 6.25 <br /> Masonry Data <br /> fm psi= <br /> Fs psi= <br /> Solid Grouting = <br /> Vertical component of active lateral soil pressure IS Modular Ratio'n' = <br /> NOT considered in the calculation of soil bearing Short Term Factor = <br /> Load Factors Equiv.Solid Thick. = <br /> Building Code IBC 2012,ACI Masonry Block Type = Medium Weight <br /> Dead Load 1.200 Masonry Design Method = ASD <br /> Live Load 1.600 Concrete Data - <br /> f c psi= 22,000.0 <br /> Earth,H 1.600 <br /> Fy psi= 40,000.0 <br /> Wind,W 1.000 <br /> Seismic, E 1.000 <br />
The URL can be used to link to this page
Your browser does not support the video tag.