My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3433 TULALIP AVE 2018-02-09
>
Address Records
>
TULALIP AVE
>
3433
>
3433 TULALIP AVE 2018-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2018 2:28:46 PM
Creation date
2/9/2018 2:28:30 PM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3433
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> . <br /> Use menu item Settings>Printing&Title Block Title Page: 1 <br /> # Dsgnr: Date: 19 JAN 2017 <br /> to set these five lines of information Description.... <br /> for your program. , <br /> This Wall in File:C:\Users\Chris\Desktop\retain pro.RPX <br /> RetainPro(c)1987-2015, Build 11.15.12.22 <br /> License:KW-06060593 Cantilevered RetainingWall Code: IBC 2012,201 318 11,201 530-11 <br /> License To:STRUCTURAL DESIGN ASSOCIATES __.. <br /> Soil Data <br /> Criteria ,; <br /> Retained Height = 5.50 ft Allow Soil Bearing = 1,500.0 psf <br /> Equivalent Fluid Pressure Method <br /> Wall height above soil = 0.50 ft Active Heel Pressure = 35.0 psf/ft <br /> Slope Behind Wall = 0.00 = <br /> Height of Soil over Toe = 6.00 in Passive Pressure = 250.0 psf/ft <br /> Water height over heel = 0.0 ft Soil Density, Heel = 110.00 pcf <br /> Soil Density,Toe = 0.00 pcf <br /> Footing]Soil Friction = 0.400 <3 __- <br /> • <br /> Soil height to ignore .- <br /> for passive pressure = 0.00 in 1 <br /> Surcharge Loads Lateral Load Applied to Stem 1 LiAdjacent Footing Load 3 <br /> Surcharge Over Heel = 100.0 psf Lateral Load = 0.0#/ft = <br /> Adjacent Footing Load 0.0 lbs <br /> Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width 0.00 ft <br /> Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity _ 0.00 in <br /> W <br /> Used for Sliding&Overturning Wall to Ftg CL Dist - 0.00 ft <br /> Load Type = Wind( ) Footing Type Line Load <br /> Axial Load Applied to Stem (Service Level) Base Above/Below Soil = <br /> 0.0 ft <br /> Axial Dead Load = 200.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall <br /> Axial Live Load = 400.0 lbs (Service Level) Poisson's Ratio = 0.300 <br /> Axial Load Eccentricity = 0.0 in <br /> Design Summary j Stem Construction Bottom <br /> Stem OK <br /> Wall Stability Ratios Design Height Above Ftg ft= 0.00 <br /> Overturning = 3.45 OK Wall Material Above"Ht" = Concrete <br /> Sliding = 1.54 OK Design Method = LRFD ASD LRFD <br /> Thickness = 8.00 <br /> Total Bearing Load = 3,332 lbs Rebar Size = # 4 <br /> ...resultant ecc. = 2.41 in Rebar Spacing = 12.00 <br /> Rebar Placed at = Edge <br /> Soil Pressure @ Toe = 1,006 psf OK Design Data -- <br /> Soil Pressure @ Heel = 561 psf OK fb/FB+fa/Fa = 0.640 <br /> Allowable = 1,500 psf Total Force @ Section <br /> Soil Pressure Less Than Allowable Service Level lbs= <br /> ACI Factored @ Toe = 1,256 psf Strength Level lbs= 1,127.0 <br /> ACI Factored @ Heel = 701 psf Moment....Actual <br /> Footing Shear @ Toe = 9.4 psi OK Service Level ft-#= <br /> Footing Shear @ Heel = 17.1 psi OK Strength Level ft-#= 2,322.8 <br /> Allowable = 75.0 psi Moment Allowable = 3,632.0 <br /> Sliding Calcs Shear Actual <br /> Lateral Sliding Force = 946.2 lbs Service Level psi= <br /> less 100%Passive Force= - 281.3 lbs <br /> less 100%Friction Force = - 1,172.7 lbs Strength Level psi= 15.0 <br /> Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 67.1 <br /> ....for 1.5 Stability = 0.0 lbs OK Wall Weight psf= 100.0 <br /> Rebar Depth 'd' in= 6.25 <br /> Masonry Data <br /> fm psi= <br /> Fs psi= <br /> Solid Grouting = <br /> Vertical component of active lateral soil pressure IS Modular Ratio'n' = <br /> NOT considered in the calculation of soil bearing Short Term Factor = <br /> Equiv. Solid Thick. = <br /> Load Factors Masonry Block Type = Medium Weight <br /> Dead Load 1.200 <br /> BuildingCode IBC 2012201 Masonry Design Method = ASD <br /> Live Load 1.600 Concrete Data <br /> 1.600 <br /> fc psi= 2,000.0 , <br /> Earth, H Fy psi= 40,000.0 <br /> Wind,W 1.000 <br /> Seismic, E 1.000 <br /> • <br /> 7 i:0/) <br />
The URL can be used to link to this page
Your browser does not support the video tag.