My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3433 TULALIP AVE 2018-02-09
>
Address Records
>
TULALIP AVE
>
3433
>
3433 TULALIP AVE 2018-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2018 2:28:46 PM
Creation date
2/9/2018 2:28:30 PM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3433
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I r r <br /> Job Truss truss Type Qty Ply Goodman/Chacon <br /> B1604635 C01 Monopitch 43 1 <br /> Job Reference(optional) <br /> ProBuild Arlington,Arlington,WA 98223 Run:13.540 s 7.64 Nov 10 2015 Print:7.640 s Nov 10 2015 MiTek Industries,Inc.Wed Sep 28 12:12:19 2016 Page 1 <br /> I D:BgYYBDaNzA3uyyAYUQwGpAyZ4Rv-GDunoQyys4T6gyzgsctrgIdXHPf_1h_NobkEVuyZ4Jg <br /> -1-0-0 0-0-0 4-0-0 <br /> 1-0-0 4-0-0 <br /> Scale=1:11.7 <br /> 3 <br /> 2x4 I <br /> 4.50 12 • <br /> 2 <br /> 2x4= 4 <br /> 2x4 II <br /> 0-0-0 4-0-0 <br /> 4-0-0 i <br /> Plate Offsets(X,Y)-- [2:0-0-5,Edge] <br /> LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.55 Vert(LL) -0.01 2-4 >999 240 MT20 185/148 <br /> TCDL 10.0 Lumber DOL 1.15 BC 0.13 Vert(CT) -0.02 2-4 >999 180 <br /> BCLL 0.0 * Rep Stress Ina YES WB 0.00 Horz(CT) -0.00 4 n/a n/a <br /> BCDL 8.0 Code IRC2015/TPI2014 (Matrix) Weight:12 lb FT=20% <br /> LUMBER- BRACING- <br /> TOP CHORD 2x4 HF Stud/Std TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except <br /> BOT CHORD 2x4 HF No.2 end verticals. <br /> WEBS 2x4 HF Stud/Std BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br /> MiTek recommends that Stabilizers and required cross bracing <br /> be installed during truss erection,in accordance with Stabilizer <br /> Installation guide. <br /> REACTIONS. (lb/size) 4=154/Mechanical,2=247/0-1-0 (min.0-1-8) <br /> Max Horz 2=50(LC 5) <br /> Max Uplift4=-14(LC 8),2=33(LC 4) <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. <br /> NOTES- <br /> 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=6.0psf;BCDL=4.8psf;h=25ft;Cat.II;Exp B;enclosed;MWFRS <br /> (envelope)gable end zone;cantilever left and right exposed;end vertical left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 <br /> 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 3)*This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit <br /> between the bottom chord and any other members. <br /> 4)Refer to girder(s)for truss to truss connections. <br /> 5)Provide mechanical connection(by others)of truss to bearing plate at joint(s)2. <br /> 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)4,2. <br /> 7)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced <br /> standard ANSI/TPI 1. <br /> 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. <br /> LOAD CASE(S) Standard <br />
The URL can be used to link to this page
Your browser does not support the video tag.