My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3433 TULALIP AVE 2018-02-09
>
Address Records
>
TULALIP AVE
>
3433
>
3433 TULALIP AVE 2018-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2018 2:28:46 PM
Creation date
2/9/2018 2:28:30 PM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3433
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job truss truss Type Qty Ply Goodman/Chacon <br /> B1604635 HRO3 CORNER RAFTER 1 2 Job Reference(optional) <br /> ProBuild Arlington,Arlington,WA 98223 Run:13.540 s 7.64 Nov 10 2015 Print:7.640 s Nov 10 2015 MiTek Industries,Inc.Wed Sep 2812:12:21 2016 Page 1 <br /> ID:BgYYBDaNzA3uyyAYUQwGpAyZ4Rv-CcOXD6_COijgvF6Dz1 wJmjisICNYHaTg FvD LZnyZ4Je <br /> -5-7-14 0-0-0 8-5-1 10-11-7 <br /> 5-7-14 8-5-1 2-6-6 <br /> Scale=1:31.5 <br /> 3x4\\ 4 <br /> 3x4\\ <br /> 3 <br /> 3.18 12 3x4 11 <br /> Io <br /> � k <br /> 3x41\ 6 A <br /> I <br /> 3x4\\ <br /> 3x4\\ 5 r <br /> 1 A a <br /> 2 1♦ <br /> c <br /> o � <br /> 1 <br /> 0-0-0 8-5-1 <br /> L. 8-5-1 <br /> LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) 1/defl L/d PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.61 Vert(LL) 0.05 2-3 >999 240 MT20 220/195 <br /> TCDL 10.0 Lumber DOL 1.15 BC 0.00 Vert(CT) 0.06 2-3 >999 180 <br /> BCLL 0.0 * Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 2 n/a n/a <br /> BCDL 8.0 Code IRC2015/TP12014 (Matrix) Weight:111 lb FT=20% <br /> LUMBER- BRACING- <br /> TOP CHORD 2x6 DF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. <br /> BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br /> REACTIONS. (Ib/size) 2=674/0-5-8 (min.0-1-8),3=300/0-2-2 (min.0-1-8) <br /> Max Horz3=133(LC 4) <br /> Max Uplift2—293(LC 4),3=106(LC 5) <br /> Max Grav2=674(LC 1),3=311(LC 35) <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. <br /> NOTES- <br /> 1)2-ply truss to be connected together as follows: <br /> Top chords connected with 10d(0.131"x3")nails as follows:2x6-2 rows staggered at 0-9-0 oc. <br /> 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply <br /> connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. <br /> 3)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=6.0psf;BCDL=4.8psf;h=25ft;Cat.II;Exp B;enclosed;MWFRS <br /> (envelope)gable end zone;cantilever left and right exposed;end vertical left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 <br /> 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 5)'This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit <br /> between the bottom chord and any other members. <br /> 6)Bearing at joint(s)2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of <br /> bearing surface. <br /> 7)Provide mechanical connection(by others)of truss to bearing plate at joint(s)3. <br /> 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)except(jt=lb)2=293, <br /> 3=106. <br /> 9)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)2,3. <br /> 10)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced <br /> standard ANSI/TPI 1. <br /> 11)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. <br /> 12)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)153 lb down and 355 lb up at 2-9-8 <br /> ,122 lb down and 336 lb up at 2-9-8,52 lb down and 105 lb up at 5-7-7,and 74 lb down and 82 lb up at 5-7-7,and 37 lb down and 47 <br /> lb up at 8-5-6 on top chord. The design/selection of such connection device(s)is the responsibility of others. <br /> LOAD CASE(S) Standard <br /> 1)Dead+Roof Live(balanced):Lumber Increase=1.15,Plate Increase=1.15 <br /> Uniform Loads(plf) <br /> Vert:1-4=-70 <br /> Concentrated Loads(Ib) <br /> Vert:3=-13(8)5=172(F=95,6=77)6=29(F) <br />
The URL can be used to link to this page
Your browser does not support the video tag.