Laserfiche WebLink
, ; , 0 <br /> Job Truss Truss Type Qty Ply Goodman/Chacon <br /> B1604635 S10 Jack-Open 2 1 <br /> Job Reference(optional) <br /> ProBuild Arlington,Arlington,WA 98223 Run:13.540 s 7.64 Nov 10 2015 Print:7.640 s Nov 10 2015 MiTek Industries,Inc.Wed Sep 28 12:12:27 2016 Page 1 <br /> ID:BgYYBDaNzA3uyyAYUQwGpAyZ4Rv-1 mNoU92zzYT_eAaMKH1j?yv9dl2hlyYergfnQyZ4JY <br /> -4-0-0 0-0-0 2-0-0 3-11-11 <br /> I <br /> 4-0-0 2-0-0 , 1-11-11 <br /> Scale=1:17.7 <br /> 3 <br /> 1el <br /> 1 r <br /> 0 <br /> 4.50hid <br /> 12 <br /> iltal v <br /> 2 N <br /> N o <br /> i _ <br /> lio <br /> ■ B1 '1 <br /> -.- I <br /> 1 <br /> 0-0-0 2-0-0 <br /> 2-0-0 <br /> LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.55 Vert(LL) 0.00 4-5 >999 240 MT20 185/148 <br /> TCDL 10.0 Lumber DOL 1.15 BC 0.38 Vert(CT) 0.00 4-5 >999 180 <br /> BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a <br /> BCDL 8.0 Code IRC2015/TPI2014 (Matrix) Weight:21 lb FT=20% <br /> LUMBER- BRACING- <br /> TOP CHORD 2x6 DF No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except <br /> BOT CHORD 2x4 HF Stud/Std end verticals. <br /> WEBS 2x4 HF Stud/Std BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br /> MiTek recommends that Stabilizers and required cross bracing <br /> be installed during truss erection,in accordance with Stabilizer <br /> Installation guide. <br /> REACTIONS. (lb/size) 5=620/0-5-8 (min.0-1-8),3=-18/0-5-8 (min.0-1-8),4=-30/Mechanical <br /> Max Horz 5=82(LC 4) <br /> Max Uplift5=161(LC 4),3=-18(LC 1),4=-30(LC 1) <br /> Max Grav5=620(LC 1),3=16(LC 4),4=17(LC 3) <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. <br /> TOP CHORD 2-5=-560/163 <br /> NOTES- <br /> 1)Wind:ASCE 7-10;Vult=110mph(3-second gust)Vasd=87mph;TCDL=6.0psf;BCDL=4.8psf;h=25ft;Cat.II;Exp B;enclosed;MWFRS <br /> (envelope)gable end zone;cantilever left and right exposed;end vertical left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 <br /> 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 3)*This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit <br /> between the bottom chord and any other members. <br /> 4)Refer to girder(s)for truss to truss connections. <br /> 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)3,4 except(jt=lb) <br /> 5=161. <br /> 6)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)3. <br /> 7)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced <br /> standard ANSI/TPI 1. <br /> 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. <br /> LOAD CASE(S) Standard <br />