Laserfiche WebLink
BeamChek v2014 licensed to:Design Lines, Inc. Reg#2308-64256 <br /> NW Dreambuilder 6030 Win Hdr <br /> M-02 Prepared by:KAD Date: 11/18/16 <br /> Selection 4x 8 DF-L#2 Lu=0.0 Ft <br /> Conditions NDS 2012 <br /> Min Bearing Area R1=2.1 in2 R2=2.1 in2 (1.5) DL Defl= 0.04 in <br /> Data Beam Span 6.25 ft Reaction 1 LL 938# Reaction 2 LL 938# <br /> Beam Wt per ft 6.17# Reaction 1 TL 1332# Reaction 2 TL 1332# <br /> Bm Wt Included 39# Maximum V 1332# <br /> Max Moment 2081 '# Max V(Reduced) 1074# <br /> TL Max Defl L/240 TL Actual Defl L/795 <br /> LL Max Defl L/360 LL Actual Defl L/>1000 <br /> Attributes Section (in3) Shear(in2) TL Defl(in) LL Defl <br /> Actual 30.66 25.38 0.09 0.06 <br /> Critical 21.34 8.95 0.31 0.21 <br /> Status OK OK OK OK <br /> Ratio 70% 35% 30% 28% <br /> Fb(psi) Fv(psi) E(psi x mil) Fc.i(psi) <br /> Values Reference Values 900 180 1.6 625 <br /> Adjusted Values 1170 180 1.6 625 <br /> Adjustments CF Size Factor 1.300 <br /> Cd Duration 1.00 1.00 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> CI Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform LL:300 Uniform TL: 420 =A <br /> Uniform Load A <br /> R1 =1332 R2=1332 <br /> SPAN=6.25 FT <br /> Uniform and partial uniform loads are lbs per lineal ft. <br />