My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2725 WETMORE AVE HUNTER LEASING 2019-12-02
>
Address Records
>
WETMORE AVE
>
2725
>
HUNTER LEASING
>
2725 WETMORE AVE HUNTER LEASING 2019-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2019 10:07:28 AM
Creation date
2/12/2018 7:38:29 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2725
Tenant Name
HUNTER LEASING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energy Code Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1-Page 2 of 7 <br /> Mechanical Permit Plans Checklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: 2724 Wetmore-Hunter Leasing Date 1/1/2015 <br /> The following Information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Location in Building Department <br /> (yes,no,na) Code Section Code Provision Information Required-Must be In permit documents Documents Notes <br /> C403.2.4.3 Stairway and shaft vent Indicate location of stairway and shaft vent dampers on plans;verify dampers are Class 1 <br /> dampers motorized;refer to HVAC System Controls for additional requirements <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that <br /> C403.2.4.4 Zone isolation dampers are expected to be occupied non-simultaneously;identify isolation zone areas on plans and <br /> locations of associated isolation dampers in HVAC distribution system;refer to HVAC System <br /> Controls for additional requirements <br /> For cooling systems with humidification equipment that are also required to have air <br /> C403.2.3.4 Humidification economizer,Indicate humidifier is adiabatic(direct evaporative or fog atomization),or <br /> exception taken <br /> Additional Efficiency Package Option,More Efficient HVAC Equipment&Fan Performance- <br /> Must comply with all 3 provisions to be eligible <br /> 0406.2.1 To comply with additional efficiency package option,calculate the percentage of heating and <br /> C403.2.3 HVAC system selection cooling equipment in the project(based on output capacity)that do not have a corresponding <br /> WSEC listed efficiency;shall be less than 10%to comply <br /> C406.2.2 Minimum equipment To comply with additional efficiency package option,Indicate that all listed heating and cooling <br /> C403.2.3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% <br /> C406.2.3 To comply with additional efficiency package option,Indicate rated FEG of stand alone fans is <br /> 0403.2.11.3 Minimum fan efficiency >_71;indicate these fans are sized so the fan efficiency at design conditions is within 10%of <br /> the maximum total or static efficiency <br /> HVAC System Controls <br /> Indicate locations of thermostatic and humidity control devices and the zones they serve on Existing <br /> plans,Including perimeter system zones location <br /> Where adjacent(neighboring)zones are controlled by separate thermostats(including <br /> perimeter systems used to offset heat gain or loss),and are connected by permanent <br /> Thermostatic controls openings>10%of either zone sf area,indicate controls configured to prevent adjacent zones <br /> Yes C403.2.4.1 (thermostats and from operating in conflicting modes(one in heat,other In cool);applies to adjacent perimeter <br /> humidistats) zones,adjacent nonperimeter zones,and adjacent perimeter and nonperimeter zones <br /> If applying Exception 2 to nonperimeter zones adjacent to perimeter zones,indicate that <br /> setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter <br /> zone does not occur until the temperature in that zone is 5°F higher than the adjacent <br /> perimeter zone temperature in heating <br /> 0403.2.4.1.1 Heat pump supplementary Indicate staged heating operation with compression as the first stage of heating and <br /> heat supplemental heating controlled with outdoor lock-out temperature set to 40°F or less <br /> 0403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that Yes <br /> control both heating and cooling <br /> If separate heating and cooling systems with separate thermostatic control devices are used to <br /> Selpoint overlap restriction serve a zone,Indicate locations of both thermostatic control devices and the zone they serve <br /> C403.2.4.1.3 (thermostats) on plans - - <br /> Indicate a limit switch,mechanical stop or DDC control with programming to prevent <br /> simultaneous heating and cooling <br /> C403.2.4.2 Automatic setback and Indicate zone thermostatic controls configured with required automatic setback and manual <br /> 0403.2.4.2.1 shutdown override functions,setback temperatures,and control method(automatic time clock or <br /> 0403.2.4.2.2 programmable controls);note exceptions taken <br /> C403.2.4.2.3 Automatic(optimum)start Indicate system controls that adjust equipment start time required to bring each area served <br /> up to design temperature just prior to scheduled occupancy <br /> C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment <br /> operation;not Including economizer cooling,night flush or IMC required OSA I exhaust <br /> C403.2.4.3 Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers(fire alarm or interruption of <br /> dampers power) <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that <br /> C403.2.4.4 Zone isolation controls are expected to be occupied non-simultaneously;Indicate controls that allow for independent <br /> space conditioning of isolation zones;or exception taken <br /> C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off <br /> heating system when area served Is unoccupied <br /> C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature <br /> exceeds 50°F and no precipitation is falling,and when outdoor air temperature exceeds 40°F <br /> 0403.2.4.6 Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F,or <br /> controls conditions protect fluid from freezing <br /> Group R1 hotel/motel For hotels and motels with over 50 guest rooms,Indicate automatic controls serving guest <br /> 0403.2.4.9 guest rooms rooms that are capable of setback(heating)and set-up(cooling)of temperature setpoint by at <br /> least 5°F;indicate control method-activated by room entry or occupancy sensor <br />
The URL can be used to link to this page
Your browser does not support the video tag.