My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10122 7TH AVE SE 2018-02-12
>
Address Records
>
7TH AVE SE
>
10122
>
10122 7TH AVE SE 2018-02-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2018 9:15:17 AM
Creation date
2/12/2018 9:14:53 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
10122
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UI3Wd UULL X UI utwcaI a.a.A... <br /> 14) <br /> LAT�°� <br /> i 1 INSULATION <br /> k ,,,,,,,,, / <br /> NORTHWEST <br /> °� H;;� <br /> Insulation Certificate /Attic Card <br /> Batts and Blankets Thermal Performance(Attic Application) <br /> When installed in accordance with the manufacturer's The stated thermal resistance(R-value)is provided by installing in accordance with the manufactuer's instructions,the required number of bags <br /> recommendations,Knauf bads and blankets will provide per 1,000 sq.ft.of net area,at not less than the labeled minimum thickness. Failure to Install both the required number of bags and at least the <br /> the full R-value. minimum thickness will result In lower insulation R-value. <br /> R-Value* Minimum Thickness R-Value* Bags/1,000 sq.ft. Maximum Coverage Minimum Weight Minimum Thickness <br /> To Obtain An insulation Installed insulation should not To Obtain an insulation The number of Contents of this bag should not The weight/SF of installed Installed insulation should <br /> resistance(R-Value)of: be less than: resistance(R-Value)of: bags/1,000 SF of net cover more than: insulation should not be not be less than: <br /> area should not be less less than: <br /> R-38HD 10.25" R-60 31.7 31.5 SF .952 LBS 19.75" <br /> R-38HD 12.00" R-50 25.8 38.7 SF .774 LBS 16.75" <br /> R-30HD 8.25" R-44 22.1 45.3 SF .663 LBS 14.75" <br /> R-30 10.00" R-38 19.0 52.7 SF .569 LBS 13.00" <br /> R-26 9.00" R-30 14.4 69.7 SF .431 LBS 10.25" <br /> R-22 6.50" R-26 12.4 80.9 SF .371 LBS 9.00" <br /> R-21 HD 5.50" R-22 10.4 95.8 SF .313 LBS 7.75" <br /> R-19 6.25"** R-19 8.9 111.8 SF .268 LBS 6.75" <br /> R-15HD 3.50" R-13 6.1 164.3 SF .183 LBS 4.75" <br /> R-13 3.50" R-11 5.1 197.6 SF .152 LBS 4.00" <br /> R-11 3.50" Bag Weight-Nominal 30 lbs.,Minimum 29 lbs. This product comforms to the performance requirements of ASTM C 764,Type I,and cancelled <br /> R-8 2.50" Federal Specification HH-I-10300,Type I,Class B. R-Values are determined in accordance with C 687 and C 518. *"R"means resistance to <br /> "R-16 In a 5.5"cavity.Conforms to ASTM C665 and heat flow. The higher the R-value,the greater the insulation power. To get the marked R-value,it Is eseential that the insulation be installed <br /> Federal Specification HH-I-521 F. properly. If you do it yourself,get instructions and follow them carefully. <br /> 61/() <br /> Equipment Required Framing Adjustment <br /> To achieve labeled R-value,this product must be applied with a pneumatic blowing machine and a To compensate for framing members,the number of bags per 1,000 sq.ft.of area to be <br /> corrugated hose with a minimum.25"internal corrugation,a minimum length of 150 ft.and a diameter of insulated should be as shown below. <br /> at least 3". Coils in the hose should not be less than 36"in diameter. Acceptable material feed rate is 5- <br /> R-Value Joist Bags/MSF 16"O.C. Bags/MSF 24"O.C. <br /> 35 lbs./minute. Recommended feed rate is 15-25 lbs./minute. <br /> Dimentions Framing Framing <br /> 2x4 31.2 31.3 <br /> Builders Insulation Statement R-60 2x6 30.8 31.1 <br /> Batts and/or blankets have been installed in conformance with the above recommendations to provide a 2x8 30.5 30.8 <br /> thermal resistance of... 2x4 25.3 25.4 <br /> R-50 2x6 25.0 25.2 <br /> R-Value Code 2x8 24.6 25.0 <br /> Attic Area R- 49 49 2x4 21.5 21.7 <br /> Sloped Ceilings R• 49 38 R-44 2x6 21.2 21.5 <br /> Walls R- R-21 R-21 2x8 20.9 21.2 <br /> Floors(over an unheated crawl space) R- R-30 R-30 2x4 18.4 18.6 <br /> R-38 2x6 18.1 18.4 <br /> Completed as of: 4/24/2017 2x8 17.8 18.2 <br /> 2x4 13.8 14.0 <br /> Site Address: Sena Investments R-30 2x6 13.5 13.8 <br /> 10122 7th Ave SE 2x8 13.3 13.6 <br /> Everett,98208 2x4 11.9 12.0 <br /> Home Builder R-26 2x6 11.6 11.8 <br /> Signature: 2x8 11.3 11.6 <br /> 2x4 9.9 10.1 <br /> Home Builder Reality Homes Inc. R-22 2x6 9.7 9.9 <br /> Address: 1308 alexander Ave E 2x8 9.7 9.7 <br /> Fife,98424 2x4 8.5 8.6 <br /> R-19 2x6 8.2 8.4 <br /> 2x8 7.9 8.2 <br /> Insulation 2x4 5.6 5.8 <br /> Contractor: Insulation Northwest LLC R-13 2x6 5.4 5.6 <br /> P.O. Box 790 2x8 5.1 5.4 <br /> Milton, WA 98354 2x4 4.6 4.7 <br /> Phone: (253)846-0121 R-11 2x6 4.3 4.5 <br /> F7v• /9x.41 AAR_RfOR OVA d-I d Q <br />
The URL can be used to link to this page
Your browser does not support the video tag.