40-27 BUILDING CAST -IN -PLACE CONCRETE <br />BRPH ARCHITECTS <br />-ENGINEERS, INC. <br />' <br />F. <br />Dry -Shake Floor Hardener Finish: After initial floating, apply dry -shake floor hardener <br />to surfaces according to manufacturer's written instructions and as follows: <br />t1. <br />Uniformly apply non -oxidizing and metallic dry -shake floor hardener at a rate of <br />150 Ib/100 sq. ft. for light reflect mineral aggregate hardener unless greater <br />' <br />amount is recommended by manufacturer. <br />2. After final floating, apply a trowel finish. Cure concrete by moist curing for 7-days <br />minimum. <br />3. Application procedures and the curing method will be based on the successful <br />test placement onsite. <br />3.10 <br />MISCELLANEOUS CONCRETE ITEMS <br />A. <br />Filling In: Fill in holes and openings left in concrete structures after work of other <br />trades is in place unless otherwise indicated. Mix, place, and cure concrete, as <br />1 <br />specified, to blend with in -place construction. Provide other miscellaneous concrete <br />filling indicated or required to complete the Work. <br />' <br />B. <br />Curbs: Provide monolithic finish to interior curbs by stripping forms while concrete is <br />still green and by steel -troweling surfaces to a hard, dense finish with corners, <br />intersections, and terminations slightly rounded. <br />C. <br />Equipment Bases and Foundations: Provide machine and equipment bases and <br />foundations as shown on Drawings. Set anchor bolts for machines and equipment at <br />correct elevations, complying with diagrams or templates from manufacturer furnishing <br />machines and equipment. <br />3.11 CONCRETE PROTECTING AND CURING <br />A. General: Protect freshly placed concrete from premature drying and excessive cold or <br />hot temperatures. Comply with ACI 306.1 for cold -weather protection and ACI 301 for <br />hot -weather protection during curing. <br />B. Evaporation Retarder: Apply evaporation retarder to unformed concrete surfaces if <br />hot, dry, or windy conditions cause moisture loss approaching 0.2 lb/sq. ft. x h before <br />and during finishing operations. Apply according to manufacturer's written instructions <br />' after placing, screeding, and bull floating or darbying concrete, but before trowel <br />finishing. <br />' C. Formed Surfaces: Cure formed concrete surfaces, including underside of beams, <br />supported slabs, and other similar surfaces. If forms remain during curing period, <br />moist cure after loosening forms. If removing forms before end of curing period, <br />' continue curing for the remainder of the curing period. <br />D. Unformed Surfaces: Begin curing immediately after finishing concrete. Cure unformed <br />surfaces, including floors and slabs, concrete floor toppings, and other surfaces. <br />C06922.001.00 03 30 04 - 15 <br />' 05-22-14 <br />