40-27 BUILDING <br />BRPH ARCHITECTS -ENGINEERS, INC. <br />PRECAST CONCRETE I <br />Place self -consolidating concrete without vibration according to PCI TR-6, <br />"Interim Guidelines for the Use of Self -Consolidating Concrete in <br />Precast/Prestressed Concrete Institute Member Plants." <br />K. Comply with PCI MNL 117 for hot- and cold -weather concrete placement. <br />L. Identify pickup points of precast concrete units and orientation in structure with <br />permanent markings, complying with markings indicated on Shop Drawings. Imprint or <br />permanently mark casting date on each architectural precast concrete unit on a surface <br />that will not show in finished structure. <br />M. Cure concrete, according to requirements in PCI MNL 117, by moisture retention <br />without heat or by accelerated heat curing using low-pressure live steam or radiant <br />heat and moisture. Cure units until compressive strength is high enough to ensure that <br />stripping does not have an effect on performance or appearance of final product. <br />N. Discard and replace precast concrete units that do not comply with requirements, <br />including structural, manufacturing tolerance, and appearance, unless repairs meet <br />requirements in PCI MNL 117 and Architect's approval. <br />2.10 INSULATED PANEL CASTING <br />A. Cast and screed supported wythe. <br />B. Place insulation boards abutting edges and ends of adjacent boards. Insert wythe <br />connectors through insulation, and consolidate concrete around connectors according <br />to connector manufacturer's written instructions. <br />C. Cast and screed top wythe to meet required finish. <br />2.11 FABRICATION TOLERANCES <br />A. Fabricate precast concrete units straight and true to size and shape with exposed ' <br />edges and corners precise and true so each finished panel complies with PCI MNL 117 <br />product tolerances as well as position tolerances for cast -in items. <br />2.12 FINISHES <br />A. Panel faces shall be free of joint marks, grain, and other obvious defects. Corners, ' <br />including false joints shall be uniform, straight, and sharp. Finish exposed -face <br />surfaces of architectural precast concrete units to match finish of panels on the existing ' <br />buildings at the site and as follows: <br />B. Formed surfaces: As -cast surface finish. <br />C. Unformed surfaces: Trowel finish. <br />C06922.001.00 <br />034500-8 ' <br />05-22-14 <br />