My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-27 2022-03-17
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-27
>
3003 W CASINO RD BLDG 40-27 2022-03-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2022 4:21:14 PM
Creation date
2/13/2018 1:19:39 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-27
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t40-27 BUILDING <br />STRUCTURAL STEEL FRAMING <br />P <br />BRPH ARCHITECTS -ENGINEERS, INC. <br />SECTION 05 12 00 - STRUCTURAL STEEL FRAMING <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS <br />A. Drawings and general provisions of the Contract, including General and <br />Supplementary Conditions and Division 01 Specification Sections, apply to this <br />Section. <br />1.2 SUMMARY <br />A. Section Includes: <br />1. Structural steel. <br />2. Field -installed shear connectors. <br />3. Grout. <br />1.3 DEFINITIONS <br />A. Structural Steel: Elements of the structural frame indicated on Drawings and as <br />described in AISC 303, "Code of Standard Practice for Steel Buildings and Bridges." <br />B. Seismic -Load -Resisting System: Elements of structural -steel frame designated as <br />"SLRS" or along grid lines designated as "SLRS" on Drawings, including columns, <br />beams, and braces and their connections. <br />C. Heavy Sections: Rolled and built-up sections as follows: <br />1. Shapes included in ASTM A 6/A 6M with flanges thicker than 1-1/2 inches. <br />2. Welded built-up members with plates thicker than 2 inches. <br />3. Column base plates thicker than 2 inches. <br />D. Protected Zone: Structural members or portions of structural members indicated as <br />"Protected Zone" on Drawings. Connections of structural and nonstructural elements to <br />protected zones are limited. <br />E. Demand Critical Welds: Those welds, the failure of which would result in significant <br />degradation of the strength and stiffness of the Seismic -Load -Resisting System and <br />which are indicated as "Demand Critical" or "Seismic Critical" on Drawings. <br />1.4 COORDINATION <br />A. Coordinate selection of shop primers with topcoats to be applied over them. Comply <br />with paint and coating manufacturers' written recommendations to ensure that shop <br />primers and topcoats are compatible with one another. <br />C06922.001.00 05 12 00 - 1 <br />1 05-22-14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.