' 40-27 BUILDING <br />ROUGH CARPENTRY <br />BRPH ARCHITECTS -ENGINEERS, INC. <br />SECTION 06 10 00 - ROUGH CARPENTRY <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. Section Includes: <br />1. Framing with dimension lumber. <br />2. Wood blocking and nailers. <br />3. Plywood backing panels. <br />4. Protective Plywood wainscot. <br />5. Flexible wood backing plates. <br />1.2 INFORMATIONAL SUBMITTALS <br />A. Evaluation Reports: For the following, from ICC-ES: <br />1. Preservative -treated wood. <br />2. Fire -retardant -treated wood. <br />PART 2 - PRODUCTS <br />2.1 WOOD PRODUCTS, GENERAL <br />A. Lumber: DOC PS 20 and applicable rules of grading agencies indicated. If no grading <br />agency is indicated, provide lumber that complies with the applicable rules of any rules - <br />writing agency certified by the ALSC Board of Review. Provide lumber graded by an <br />agency certified by the ALSC Board of Review to inspect and grade lumber under the <br />rules indicated. <br />1. Factory mark each piece of lumber with grade stamp of grading agency. <br />2. Provide dressed lumber, S4S, unless otherwise indicated. <br />B. Maximum Moisture Content of Lumber: 15 percent for 2-inch nominal thickness or <br />less, 19 percent for more than 2-inch nominal thickness. <br />2.2 WOOD -PRESERVATIVE -TREATED MATERIALS <br />A. Preservative Treatment by Pressure Process: AWPA U1; Use Category UC2 for <br />interior construction not in contact with the ground, Use Category UC3b for exterior <br />construction not in contact with the ground. <br />1. Preservative Chemicals: Acceptable to authorities having jurisdiction and <br />containing no arsenic or chromium. <br />061000-1 <br />05-22-14 <br />C06922.001.00 <br />