My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-27 2022-03-17
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-27
>
3003 W CASINO RD BLDG 40-27 2022-03-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2022 4:21:14 PM
Creation date
2/13/2018 1:19:39 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-27
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
40-27 BUILDING INSULATED CORE METAL WALL PANELS <br />BRPH ARCHITECTS -ENGINEERS, INC. <br />SECTION 07 42 16 - INSULATED CORE METAL WALL PANELS <br />' PART 1 - GENERAL <br />' 1.1 SECTION INCLUDES <br />A. Foamed -insulation -core vertical metal wall panel assembly, with related metal trim and <br />accessories. <br />1.2 RELATED REQUIREMENTS <br />A. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal copings, flashings, <br />reglets and roof drainage items not specified in this Section. <br />B. Division 07 Section "Joint Sealants" for field -applied joint sealants. <br />C. Division 07 Section "Formed Metal Wall Panels" for exposed -fastener, single -skin wall <br />panels. <br />1.3 PERFORMANCE REQUIREMENTS <br />A. Wall System Design: Provide metal wall panel assemblies capable of withstanding the <br />effects of gravity loads and the following loads and stresses within limits and under <br />conditions indicated, per ASTM E 72. Provide a metal wall panel system that is <br />identical to systems that have been successfully tested by a qualified testing and <br />inspecting agency to resist wind pressures calculated in accordance with 2012 IBC and <br />ASCE 7: <br />1. Design wind loads: <br />a. Outward wall pressure, Zone 4: -25.5 lb/sq. ft. <br />b. Outward wall pressure, Zone 5: -46.6 lb/sq. ft. <br />C. Inward wall pressure: 25.5 lb/sq. ft. <br />2. Deflection limits: Withstand test pressures of 150 percent of inward and outward <br />wind -load design pressures with maximum deflection of 1/180 of the span with no <br />evidence of failure. <br />3. Seismic Performance: Comply with ASCE 7 Sections 9, "Earthquake Loads." <br />B. FM Global Listing: Provide metal wall panels that are listed in FM Global's "Approval <br />Guide" for noncombustible construction. Identify materials with FM Global markings. <br />C. Delegated Design: Engage a qualified engineer to provide design and engineering <br />analysis of composite wall panel system, including secondary framing, based on <br />project performance requirements and design criteria. <br />C06922.001.00 <br />074216-1 <br />05-22-14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.