My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2407 PINE ST B 2018-02-22
>
Address Records
>
PINE ST
>
2407
>
2407 PINE ST B 2018-02-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2018 9:20:02 AM
Creation date
2/22/2018 9:19:58 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
2407
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br /> • <br /> pc› <br /> ENGINEERING / PUBLIC SERVICES DEPARTMENT <br /> Lz/z <br /> ,7,17 <br /> November 13, 2006 <br /> Ms. Ba bara Burks <br /> 1064 Cedar Avenue <br /> Marysv lie, WA 98270 <br /> Subject Project: Burks • <br /> Job Address: 2407-B Pine Street <br /> Plan Check No: C0611-002 <br /> Dear Ms. Burks: <br /> In response to your application for a construction permit, your pians have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These. comments address building issues only Additional revisions or additions may be <br /> • required by other departments (Such as Utilities, Planning or Fire). All references refer to the <br /> 2003 Liternational Residential Code, as amended by the State of Washington and/or <br /> Washington State Energy Code 2004 Edition, and adopted by the City of Everett, unless stated <br /> otherwise. <br /> In order for the processing of your application to continue, it will be <br /> necessary to provide the Building Division with two complete new sets of <br /> drawings reflecting the corrections requested. <br /> 1. 4 x 10 beam appears to be overstressed. Provide size species and grade of beam. <br /> Show enough of the existing building framing f6-5alcilate the loads on the beam <br /> (provide building section). <br /> 2. Provide 50 cfrn fan in bathroom and 100 cfm fan in kitchen. <br /> • 3. Provide 110 volt smoke alarm in all sleeping rooms and in the corridor or area giving <br /> access to each separate sleeping area. Detectors shall be interconnected and have <br /> battery back-up. <br /> 4. Provide,window sizes to verify that light and ventilation requirements are provided. <br /> 5. Provide minimum 36" landing on outside of the exterior door. Show on plans. <br /> 6. Specify anchor bolt size and spacing 7" minimum embedment,im,inimum 2 each piece <br /> and within 12" of each end of each piece. Provide 3 x 3". x A plate washer on al <br /> anchor bolts in braced wall lines. <br /> CITY OF EVERETT• 3200 Cedar Street• Everett,WA 98201 • (425)257-8800• Fax(425)257-8856 <br /> tellIKILIMSTRJHEILMANIC0611-002(240743 PINE ST) ei <br /> I. <br />
The URL can be used to link to this page
Your browser does not support the video tag.