• • <br /> ` Wall Panel Systems. 07410 <br /> Benchmark Architectural Systems,Inc. , <br /> I. Abrasion Resistance plumb in order to provide the proper <br /> ASTM D 968—minimum support for the wall panels as well as <br /> 60 liters of sand per mil fenestration. <br /> before the appearance of <br /> 5. Core Insulation: base metal. C. In any case,all materials must be <br /> a. Shall be expanded PART 3 EXECUTION installed in strict accordance with <br /> polystyrene(EPS),Report 3.01 FABRICATION approved shop/erection drawings. <br /> No.NER-479,nominal <br /> density 1.0 pcf with A. Comply with dimensions,profile •' D. Remove strippable peelcoat <br /> minimum shear strength of limitations,gauges,and fabrication immediately after each panel is <br /> 20 psi,Flame Spread of details as shown,and if not shown, installed. Remove and replace any <br /> 10,and Smoke Developed provide Benchmark standard product panel found to be defective or <br /> of 130. R-Value of 4.17 fabrication. damaged prior to installing the next <br /> .eciooh thickness. panel and notify manufacturer. <br /> b. Alternate—modified B. Fabricate components of the system <br /> isocynurate,nominal at factory,ready for field assembly. 3.05 DAMAGED MATERIAL <br /> density 2.0 pcf,with <br /> minimum shear strength of C. Fabricate components and assemble A. Repair or replace all damaged <br /> 24 psi,Flame Spread of units to comply with fire and material to the satisfaction of the <br /> 25,and Smoke Developed performance requirements specified. architect and/or contractor if damage <br /> of 90. R-Value of 7.14 per has been caused by manufacturer or <br /> inc ,', ness. D. Apply specified finishes in wall panel erector. The general <br /> C. Structure 'dhesive s - c• conformance with manufacturer's Contractor or builder shall be <br /> approved,Type II,Class 2 meeting standards,and coating manufacturer's responsible for the protection of <br /> Acceptance Criteria for Sandwich instruction. completed or Installed walls from <br /> Panel Adhesives,(Report No.NER- damage by other trades. Installed <br /> 457). E. Changes of plane,parallel or areas or portions of the work shall be <br /> transverse to longitudinal axis,shall inspected by the owner or general <br /> D. Finishes: be accomplished as detailed on contractor and approved immediately <br /> 1. Accelerated Testing—Finished drawings. following the completion of such <br /> Color Coating 1.0 mil total OFT: areas. Any subsequent damage will <br /> a. Salt Spray ASTM B 117, 3.02 APPROVED SHOP/ERECTION DRAWINGS then be the responsibility of others. <br /> 1000 hrs—shall have no <br /> more than 1/16"edge A. Furnish shop drawings complete with 3.06 CLEANING <br /> creepage from score with details of all major interfaces and <br /> test rating of 7 per ASTM periphery conditions. A. The panel erecting contractors shall <br /> D 1654 and ASTM Cr 714. provide a dry wipe-down cleaning of <br /> b. Weatherometer ASTM G B. Shop drawings shall specify and all work as it is erected and prior to <br /> 23,5000 hrs—No indicate all materials furnished as well moving to the next portion or area. <br /> cracking,peeling, as finishes to be applied. <br /> blistering,loss of B. The general contractor and/or owner <br /> adhesion,or corrosion of C. These shop drawings shall also serve shall be responsible for the <br /> base metal. Chalk rating as field installation drawings and be subsequent and final cleaning of the <br /> of 10 per ASTM D 659 and complete with specific instructions for wall system. <br /> ASTM D 4214. Less than the application•of the products, <br /> 2 NBS units color change periphery trim,sealants,lap strips,etc. <br /> per ASTM D 2244. to insure a weather tight installation. <br /> c. Impact ASTM D 2794, <br /> reverse and direct—No 3.03 INSPECTION <br /> cracking or loss of <br /> adhesion using 80 inch- A. Examine alignment of structural steel <br /> lbs.And 5/8"ball Indenter. and/or wall panel support systems <br /> d. Acid Resistance ASTM D prior to installation and do not proceed <br /> 1308,10%hydrochloric until any defects are corrected by <br /> solution and 10%sulfuric responsible contractor. Building <br /> solution—no visible tolerances shall not exceed <br /> changes after 24 hr. maximums as defined in AISC or ACI <br /> exposure. specifications. <br /> e. Specular Gloss ASTM D <br /> 523 @ 60 degrees—range B. Inspect all material included in this <br /> of 30±5 as measured on contract prior to installation. <br /> Bky-Gardner 4520 Manufacturer to be notified of any <br /> glossmeter. unacceptable material prior to <br /> f. Pencil Hardness ASTM D installation on the wall. <br /> 3363—HB minimum using <br /> Eagle Turquoise pencils. C. When necessary,contractor to provide <br /> g. Formability ASTM D 522, field measurements as requested by <br /> 180 degree bend over a manufacturer in order to achieve <br /> 1/8"mandrel—no proper geometric fit of wall panel <br /> evidence of cracking and system. <br /> no loss of adhesion to the <br /> point of metal rupture. 3.04 INSTALLATION AND ERECTION <br /> h. Humidity Test ASTM D <br /> 2247,1000 hrs @ 100% A. Install metal wail panels,fasteners, <br /> humidity and 100°F—test trim and related items in accordance <br /> rating of 10,no scribe with approved shop/erection drawings <br /> creep,no blistering, and manufacturer's installation . <br /> cracking,or corrosion per -instructions. <br /> ASTM D 1654 and ASTM <br /> D 714. B. The installation of the girt/support and <br /> anchoring systems shall be true and <br /> Kynar 500®is a registered trademark of Elf Atochem North America,Inc. 1 'p <br /> ,,+ <br /> Kylar 5009 is a registered trademark of Ausimont U.S.A.Inc. <br /> 1 . i <br />