My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2427 ROCKEFELLER AVE 2018-02-23
>
Address Records
>
ROCKEFELLER AVE
>
2427
>
2427 ROCKEFELLER AVE 2018-02-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2018 11:30:10 AM
Creation date
2/23/2018 11:30:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2427
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ted Budden <br /> From: Ted Budden <br /> Sent: Tuesday, September 03, 2013 8:27 AM <br /> To: Tony Lee <br /> Cc: Kevin Fagerstrom <br /> Subject: 2427 Rockefeller <br /> Tony, <br /> I have prepared a brief summery related to our observations during our site visit at 2427 Rockefeller on August 28`h <br /> 20013, here is the breakdown. <br /> 1. Electrical wiring observed in the attic area of the building has open splices. Knob and tube wiring has been tampered <br /> with is improperly connected and is not safe nor approved for use in its current condition. Flexible cord is being used in <br /> place of permanent wiring. Electrical receptacles have been incorrectly wired. <br /> 2.The building has been altered from its original condition to include several additional sleeping rooms and at least one <br /> additional kitchen. No access was granted to the majority of these tenant sleeping rooms as these rooms were currently <br /> occupied.The size of these rooms and whether approved egress and rescue openings and required smoke alarms are <br /> provided is not known. Permits and approvals for these alterations have not been granted according to my research of <br /> city records. <br /> 3.A common living area and eating area for all of the tenants of this building does not appear to be provided. <br /> A� .The gas fired heating and hot water equipment that serves this building lacks adequate required combustion air <br /> supply.This condition can cause carbon monoxide to enter the building.This is a life safety hazard to the occupants of <br /> this building. <br /> 5.The hot water tank that serves this building is inadequately sized for the number of occupants that rely on it for their <br /> hot water needs.The"first hour" rating of this tank is too small for the demand. <br /> 6.The electrical service entrance conductors and meter base are undersized for this building.The electrical panel also <br /> lacks knockout covers where holes have been created and or breakers removed. <br /> These observations do not represent a complete list of all of the code violations present in this building.The <br /> documented and observed code violations in this building are however,very significant. Based on our observations,this <br /> building is a Dangerous Building as defined by the International Property Maintenance Code. <br /> It is my understanding that this building has been condemned by the Code Enforcement Unit. I completely agree with <br /> this determination and highly recommend that the building be immediately vacated until corrections to the building <br /> have been made and approval for occupancy by this office has been granted. <br /> Regards. <br /> Ted Budden <br />
The URL can be used to link to this page
Your browser does not support the video tag.