My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2018-02-23
>
Address Records
>
RUCKER AVE
>
3020
>
SNO CO HEALTH DISTRICT
>
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2018-02-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2018 1:34:32 PM
Creation date
2/23/2018 1:34:25 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3020
Tenant Name
SNO CO HEALTH DISTRICT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Small Sunline (3-6 Ton Page:8 <br /> ayomcPackage) N543 <br /> Single Package R-410A Heat Pump <br /> Project Name: SNOHOMISH 37 Unit Model#: XN036C00A2C1AAA1A1 <br /> Quantity: 1 Tag#:IN STOCK--DIRECT System: XN036C00A2C1AAA1A1 <br /> REPL <br /> Cooling Performance <br /> Total gross capacity 39.0 MBH ' <br /> Sensible gross capacity 28.5 MBH <br /> Seasonal Efficiency(at ARI) 14.00 SEER <br /> Efficiency(at ARI) 12.00 EER )P ', <br /> Ambient DB temp. 95.0 °F <br /> Entering DB temp. 80.0 °F <br /> Entering WB temp. 67.0 °F � <br /> Leaving DB temp. 58.0 °F ' � __ ;, <br /> Leaving WB temp. 56.6 °F <br /> Power input(w/o blower) 2.80 kW <br /> Sound power 76 dB(A) <br /> Refrigerant " <br /> Refrigerant type R-410A ' <br /> Heat Pump Performance <br /> Ambient DB temp. 47 °F i <br /> HSPF 8 <br /> Capacity @ 47°F 36.00 MBH 3 Ton <br /> COP @ 17°F 2.20 • York Units are Manufactured at an ISO 9001 Registered Facility and Each <br /> COP @ 47°F 3.35 <br /> Capacity @ 17°F 19.00 MBH Rooftop is Completely Computer-Run Tested Prior to Shipment. <br /> Supply Air Blower Performance Unit Features <br /> Supply air 1200 CFM • Single Stage Cooling <br /> Ext.static pressure 0.57 IWG • Single Stage Cooling <br /> Addl.Unit Losses(Options/Accessories) 0.08 IWG • Full Perimeter Base Rails with Built in Rigging Capabilities <br /> Blower speed 880 RPM • Unit Cabinet Constructed of Powder Painted Steel,Certified Al.1000 Hours <br /> Duct location Bottom Salt Spray Test(ASTM B-117 Standards) <br /> Motor rating 0.75 HP <br /> Actual required BHP 0.35 HP • Either Supply and/or Return can be Field Converted from Vertical to <br /> Power input 0.32 kW Horizontal Configuration without Cutting Panels. <br /> Elevation 0 ft. • Scroll Compressor <br /> Drive type DIRECT • Dry Bulb Economizer and Hood(No Barometric Relief Damper)with <br /> Speed tap 4 Economizer Fault Detection&Diagnostic(Meets ASHRAE 90.1-2013,IECC <br /> Electrical Data 2015,California Title 24,AMCA 511) <br /> Power supply 230-3-60 • 3/4 HP Direct Drive Blower <br /> Unit min circuit ampacity 21.3 Amps • Unit Ships with 1"Throwaway Filters <br /> Unit max over-current protection 30 Amps • Solid Core Liquid Line Filter Driers <br /> Dimensions&Weight • Replacement Filters:2-(15"x 20"x 1"or 2")and 1 -(14"x 25"x 1"or 2"). <br /> Hgt 33 in. Len 83 in. Wth 45 in. Unit accepts 1"or 2"wide filters. <br /> Weight with factory installed options 665 lbs. • Through-the-Curb and Through-The-Base Utility Connections <br /> Clearances • Single Point Power Connection <br /> Right 24 in. Front 24 in. Back 36 in. • Short Circuit Current:5kA RMS Symmetrical <br /> `Top 72 in. Bottom 0 in. Left 36 in. i • Copper Tube/Aluminum Fin Condenser Coil,Copper Tube/Aluminum Fin <br /> Note: Please refer to the tech guide for listed maximum static pressures Evaporator Coil <br /> • Galvanized Steel Drain Pan <br /> aMeRicaej S�® _.r � ,•-•,-.� • Standard Access Doors <br /> A D.QCERTIFIEUALITY -fe, <br /> —.°'"*"."'YwCc usamiam Standard Unit Controller: Simplicity Control Board <br /> • An Integrated Low-Ambient Control,Anti-Short Cycle Protection, Lead-Lag, <br /> Fan On and Fan off Delays,Low Voltage Protection,On-Board Diagnostic <br /> and Fault Code Display.Allows all units to operate in the cooling mode down <br /> to 0°F outdoor ambient without additional components or intervention. <br /> • Safety Monitoring-Monitors the High and Low-Pressure Switches,the <br /> Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch <br /> on Gas and Electric Heat Units.The Unit Control Board will Alarm on Ignition <br /> Failures,Safety Lockouts and Repeated Limit Switch Trips. <br /> BAS Controller <br /> • Simplicity SE Controller including Discharge Air,Return Air,and Outdoor Air <br /> Temperature Sensors <br /> Warranty <br /> • One(1)Year Limited Warranty on the Complete Unit <br /> • Five(5)Year Warranty-Compressors and Electric Heater Elements <br /> Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 05/15/2017 /��/K1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.