Laserfiche WebLink
J <br /> r��7�y� Page 1 of 1 <br /> ...... aZa1.. &Associates, Inc. Field <br /> Geotechnical Engineering• Environmental Engineering Report NO.:09616422DFR12222016HM <br /> Construction Testing and Inspection <br /> DATE: 12/22/2016 Set Count: CONTRACTOR: Newland Construction <br /> PROJECT#: 09616422 PERMIT#: <br /> PROJECT: Puget Sound Kidney INSPECTOR: Hossein Mansouri <br /> LOCATION: 1005 Pacific Ave. JURISDICTION: City of Everett <br /> KA P.M.: Jeff Mercer WEATHER: Cloudy TEMP:42°F <br /> Re-Steel Inspection: <br /> Krazan representative arrived onsite per contractor's request to perform re-steel inspection on CMU,stem,and planter wall <br /> footings at gridlines D.2/2.4-4. Re-steel inspection was performed per approved design plans sheets S2.0 ;4,5,12/S3.0 and <br /> all re-steel were checked for grade,size,lap splices,and clearances. <br /> Concrete Placement Inspection: <br /> Onsite to perform concrete pour observation and sampling on CMU, stem, and planter wall footings. Contractor poured a <br /> total of 9.5 CY of concrete(Miles)using approved mix design 0740AG3 having minimum compressive strength design of <br /> 4,000 psi at 28 days.One set of five 4x8 concrete cylinders was cast for compressive strength testing marked as set#1. <br /> Test results are available on concrete report#9616422CR12222016HM-1 <br /> ‘ q 4 I t fi I 17- 1 <br /> M1 -" r :if � <br /> ....*,14-,-, �� � g... <br /> --' i.11 <br /> it ,... <br /> : "`� — .• •gym_ 4.:1 i-' A ' t •.' rt''": <br /> ,,i., ---,-- ---- <br /> • <br /> • <br /> fi. '� / <br /> . 10;.:.. 1;,,,,',Pet..,,, „.:'.-) <br /> • <br /> `t'tity t .. e", '"": . 1 <br /> Reviewed By: ASTM Test#: Asset Number(s): <br /> To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and <br /> regulatory requirements. <br /> Superintendent/Representative: Technician: <br /> Or <br /> Offices Serving the Western United States <br /> Lynnwood (425)485-5519 • Poulsbo (360) 598-2126 • Puyallup(253) 939-2500 , <br /> The information provided on this report is prepared for the exclusive use of the client.This report may not be reproduced in any format without the written permission of the client and Krarin&Associates.This repos it, �{f <br /> indicates our inspectors observation and testing results based on so,condition and contractor activities.This information is subject to review prior to final submittal. By signing this report.our inspector docs not accept ' <br /> responsibility for validity of results.The same information has been provided by others on site l <br />