Laserfiche WebLink
CONCRETE <br /> 410 . •••••••••••• GILD l&A s s o c i a t e s, I n c. REPORT NO.: 16422CR122216-HM -1 <br /> Geotechnical Engineering•Environmental Engineering <br /> Construction Testing and Inspection <br /> DATE: 12/22/2016 CONTRACTOR: Newland Construction <br /> PROJECT#: 09616422 PERMIT#: <br /> PROJECT: Puget Sound Kidney INSPECTOR: Hossein Mansouri <br /> LOCATION: 1005 Pacific Ave. JURISDICTION: City of Everett <br /> KA P.M.: Jeff Mercer WEATHER: Cloudy TEMP: 42 ° <br /> Field Data Reported Batch DATA <br /> Concrete: X Other: Cement Type I/Il <br /> Supplier: Miles Plant No. Site Mix: Design Actual <br /> Slump Mix Air Unit Mix No. 0740AG3 <br /> Time Truck# Ticket# %Air Inch Temp(F) Temp(F) Weight cern.Lbs. 570 567 <br /> 12:00 C013 186654 - 5-1/4 66° 42° - F.Ash lbs. <br /> C.Agg.Lbs pea 1700 1702 <br /> C.Agg.Lbs <br /> C.Agg.Lbs <br /> Placement Area Sand lbs 1440 1440 <br /> Location: CMU, stem, and planter wall footings Water 258 238 <br /> Admixture glen 17 17 <br /> Admixture poly 34 34 <br /> Admixture <br /> Air Ent. 2 2 <br /> IOzIcwt-I <br /> Water Added On Job Site <br /> Remarks: Concrete place by pump and consolidated mechanically. (Gals.) 21 <br /> Field Test <br /> Please Refer To Field Repot Number: 09616422DFR12222016HM ASTM Method <br /> C143 7 C138 <br /> C1064 7 C173 <br /> Inspector: Hossein Mansouri C31 7 Other <br /> ') Laboratory Data Design Strength: 4000 @ 28 days Date Specimens Rec'd: 12/23/2017 <br /> Cyl. Test Field Wt. Max Comp. Set Tested Brk Test Method <br /> Code Date Cure Age Dim. Area # Load Strength # By Typ ASTM C39 <br /> 57199-1 12/29/16 7 4x8 12.56 - -- 47820 3810 1 CM 3 ASTM C109 <br /> 57199-2 1/19/17 28 4x8 12.56 -- 63710 5070 1 RG 2 ASTM C617 <br /> 57199-3 1/19/17 28 4x8 12.56 -- 65220 5190 1 RG 3 ASTM C1231 ✓ <br /> 57199-4 1/19/17 28 4x8 12.56 -- 62790 5000 1 RG 3 ASTM C1019 <br /> 57199-5 1/19/17 28 4x8 12.56 -- 64470 5130 1 RG 1 OTHER <br /> Test Results <br /> Remarks: <br /> Results Reviewed B 'L Conforming <br /> y 2.� Date: /-- Z 3-r1 <br /> ` j I <br /> Codes for Break Types: I I ! . i :j ", 1 <br /> J i f <br /> 1 2 3 4 5 `6 <br /> Offices Serving The Western United States <br /> Concrete Report <br /> Lynnwood(425)485-5519 • Poulsbo(360) 598-2126 • Puyallup (253) 939-2500 <br /> The Information prodded on this report is prepared for the esduWve use of the client,and may not be reproduced In any format ruiner&the written permission or the client end weaan is Associates.This report tdicates our inspector's observation and testing results based on see condition& <br /> end oontrade activities This information is ambled to review prior to final submetal.By signing tins report.our inspector aces not accept responsibility for veidM of mutes.The same information has been provided by others on site. / <br />