Laserfiche WebLink
Interior Lighting Summary - Space-By-Space LTG-INT-SPACE <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address PSKC Everett Remodel Date 5/20/2016 <br /> Lighting Alterations, Renovations & Building Additions For Building Department Use <br /> O Less than 60% 0 60%or more O Stand alone 0 Addition <br /> fixtures replaced fixtures bldg.addition combined <br /> Notes: <br /> a. Lighting fixtures in a building addition may comply as a stand alone project,or they maybe <br /> combined Kith the overall existing bldg lighting to demonstrate compliance.Refer to <br /> C101.4.3. <br /> b.For retrofits and building additions,provide Space Types and gross interior areas in the <br /> Maximum Allotted Lighting table.If a builidng addition trill comply as combined Wth the <br /> overall <br /> existing builidng,include all applicable existing Space Types and gross interior areas. <br /> c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> a. lr less man bu"/n or existing nxrures wit oe replacea,proviae total existing ngnrtng uenage <br /> Ma i4linlitto Jlk W eilickightitag 411i W Allotted Lighting table. <br /> Location(plan# /nowea Bross interior watts Anowea <br /> room#) Space Type* Watts per ft2 Area in ft2 (watts/ex area) <br /> 213 Classroom/lecture/training 1.24 371 460 <br /> 114,209,212,214- <br /> 216,219,220,227, Office-Enclosed 1.11 2986 3314 <br /> 228,231-235 <br /> 202,103,102 Lobby 0.90 1342 1208 <br /> 208,207,204, Restroom 0.98 601 589 <br /> 105,104 <br /> 101,201 Stairway 0.69 244 168 <br /> 103,205,222,229 Storage 0.63 443 279 <br /> 110,111,106,211,20 <br /> 6,218,217,203,226, Health care clinic/hospital:Corridors/transition 0.89 1942 1728 <br /> 230 <br /> 116,115,225 Health care clinic/hospital:Exam/treatment 1.66 4537 7531 <br /> 112,113 Health care clinic/hospital:Medical supplies 1.27 169 215 <br /> 223 Health care clinic/hospital:Nurse station 0.87 269 234 <br /> 107 Workshop 1.59 694 1103 <br /> 210 Dining area:Bar/loungelleisure dining 1.31 653 855 <br /> 221 Laboratory for medicallindustrial/research 1.81 88 159 <br /> Atnum'^' enter <br /> ygyxisfing Lighting Enter Exist <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> * Select Table C405.5.2(2)category from drop dottn menu. Area Allowed Watts <br /> ** For atriums,indicate height.Allotted wattage for first 40 feet is 0.03 Wilt. ht, Total 14339 17845 <br /> above 40 feet is 0.02 Witt. ht. <br /> Proposed Lighting Wattage <br /> Location(plan# Number of Watts/ Watts <br /> room#) Fixture Description*** Fixtures Fixture Proposed <br /> Fl 2X4 LED RECESSED ACRYLIC-4000 LUMENS 104 39 4056 <br /> FIA 2X4 LED RECESSED ACRYLIC-3000 LUMENS 28 31 868 <br /> F2 2X2 LED RECESSED 14 21 294 <br /> F3 2X4 LED PRISMATIC 4 39 156 <br /> F4 4FT LED STRIP 10 25 250 <br /> F5 4FT LED UNDERCABINET 13 30 390 <br /> F6 4FT LED LINEAR SLOT LIGHT 8 40 320 <br /> F6A 6FT LED LINEAR SLOT LIGHT 4 60 240 <br /> F7 6"DIA LED DOWNLIGHT 14 19 266 <br /> F8 6"DIA LED DOWNLIGHT-ARCHITECTURAL 28 14 392 <br /> F9 6"DIA LED DOWNLIGHT-CYLINDER 4 24 96 <br /> X LED EXIT SIGN 17 3 51 <br /> X1 EMERGENCY UNIT WITH ADJUSTABLE LED HEADS 2 3 6 <br /> Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allotted Watts for Interior Lighting Total Proposed Wat 7385 <br /> ***Include existing to remain lighting fixtures and exempt lighting equipment per notes below (...-/5). <br />