PUBLIC WORKS <br /> ENGINEERING /PUBLIC SERVICES DEPARTMENT <br /> April 27, 2016 <br /> Andrew Kristovich <br /> andrewk@gravitythieves.com <br /> RE: Owner: Swallwell's First LLC <br /> Job Address: 2916 State St <br /> Plan Check No: B1603-038 <br /> Dear Mr. Kristovich, <br /> In response to your application for a construction permit, your plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and respond to the <br /> comments below. These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the 2012 <br /> International Building Code (IBC), the 2012 International Fire Code (IFC), the 2012 International <br /> Mechanical Code (IMC), and the 2012 International Energy Conservation (IECC), as amended by the <br /> State of Washington and adopted by the city of Everett. The current IBC referenced standard for <br /> accessible design is the 2009"Accessible and Usable Buildings and Facilities"(ICC/ANSI A117.1). Federal <br /> ADA, FHA, and HUD regulations and standards, including the Fair Housing Accessibility Guidelines may be <br /> more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two complete new sets of construction documents reflecting the <br /> corrections requested. <br /> 1. Regarding Item 1 of the previous letter and item 4 of the first letter; IBC 414 requires the floor <br /> assembly of the control area to have a fire-resistance rating of not less than 2 hours. IBC <br /> 722.6.1.1 prohibits calculated fire resistance ratings when the necessary rating exceeds 1 hour. <br /> Please provide the detailing and testing agency I.D. number for a floor/ceiling assembly rated for <br /> 2 hours. <br /> If you have any questions, please call me at 425-257-7264. <br /> Upon submittal of the drawings, your application will be given priority and plan reviews will recommence. <br /> All required submittals shall be sufficient detail and contain sufficient information to ensure that the <br /> proposed structure will be constructed in compliance with all adopted codes. <br /> } <br /> Sincerely, <br /> Steve Miller <br /> Associate Engineer <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (425) 257-8200 • Fax (425) 257-8856 <br />