, <br /> LI KirklandDynamiCs <br /> Pressure Relief Valve Set Pressure = 120 psi (NFPA 58,5.7.2.5(A)) C13.1 <br /> **See calculation C34.2 for Maximum Allowable Working Pressure (MAWP) <br /> Pressure Relief Valve Flow Rate (min.)= 53.632 x A(NFPA 58, 5.7.2.6) <br /> 53.632 x 367 in2 x 1/144 <br /> 136 CFM (Collection Vessel) C13.2 <br /> The Pressure Relief Valve meets all operational requirements of the system such as fluid contact,cold <br /> temperature (-29 degrees F) and corrosion resistance. A second PRV has been added to the Material <br /> vessel of the Extractor. The system has two (2)total PRV's. <br /> Item 3/ Item 11—Pressure Gauge <br /> r <br /> ✓ <br /> wi <br /> .I .iQ . c <br /> W4 � 1 <br /> A'y.7 M <br /> Ti <br /> _ s <br /> • <br /> w. <br /> Figure 13.1—Yellow Jacket Pressure Gauge, UPC 49002, -30 psi to 120 psi <br /> UPC:49002, 3-1/8" Blue Compound Pressure Gauge <br /> Gauge Retard Pressure equals 350 Psi <br /> Gauge is rated for use up to 500 Psi <br /> Yellow Jacket Products Division <br /> Ritchie Engineering Company, Inc. <br /> 10950 Hampshire Avenue South <br /> Bloomington, MN 55438 USA <br /> (952) 943-1300 <br /> 9/1/2015 Project: 150703 Terpp MK IV CLE Report Page 13 of 44 <br /> KD Doc. 150703ER <br />