Laserfiche WebLink
•• • 11E4 KirklandDynamics <br /> } Certificate of Compliance: <br /> The Professional Closed-Loop Extractor has been reviewed by a Kirkland Dynamics Engineer of Record <br /> and meets all the requirements established by 314-55-104 WAC for a Professional Grade Closed Loop <br /> Extractor as noted within this report. Applies only to Terpp Extractors MK 4c Model manufactured by <br /> Terpp Extractors. Each manufactured unit shall include an individual Certificate of Conformance issued <br /> by Terpp Extractors. <br /> The following Codes, Standards and rules have been evaluated: <br /> Title 296 WAC <br /> International Building Code 2012 <br /> International Mechanical Code 2012 <br /> International Fire Code 2012 <br /> NFPA 58-2014 Liquefied Petroleum Gas Code <br /> NFPA 497-2012 Recommended Practice for the Classification of Flammable Liquids, Gases, or Vapors <br /> and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas <br /> NFPA 70-2014 National Electrical Code <br /> ASME BPVC VIII Division 1-2013 <br /> Serial Number Provided by Terpp Extractors after completion of ASME BPVC VIII Pressure Test(See <br /> • manufacturer issued Certificate of Conformance). <br /> Washington State Registered Engineer: <br /> Digital Signature—Thomas J. Olson <br /> Thomas J. Olson,Jr <br /> 425-495-0081 <br /> tom@kirklanddynamics.com <br /> License Number: 48961 <br /> Kirkland Dynamics, LLC. <br /> 11731 120th Avenue NE, Suite B <br /> Kirkland, WA, 98034 <br /> 425-495-0081 <br /> 9/1/2015 Project: 150703 Terpp MK IV CLE Report Page 44 of 44 <br /> KD Doc. 150703ER <br /> 4 <br />