My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
420 VIEW RIDGE DR 2018-02-26
>
Address Records
>
VIEW RIDGE DR
>
420
>
420 VIEW RIDGE DR 2018-02-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2018 1:33:37 PM
Creation date
2/26/2018 1:33:32 PM
Metadata
Fields
Template:
Address Document
Street Name
VIEW RIDGE DR
Street Number
420
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR <br /> PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED <br /> Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed <br /> in this Checklist.All project plans and supporting documentation must be provided on site for the inspector. <br /> TO BE COMPLETED BY APPLICANT <br /> 0 Project Information <br /> Shelon Property Owner Name: Suzy Oversvee <br /> Project Address: 420 View Ridge Drive Parcel# 00606100001000 <br /> City: Everett State: ZIP: 98203 <br /> Day Phone: (202)213-8874 <br /> Contractor Name A&R SOlar <br /> Contractor License It: RSOLAS*903JM <br /> Contractor Day Phone: 206-707-9937 <br /> PV system description Installing a 9 kW Photovoltaic System on the roof. <br /> (include manufacturer (30) Itek Energy 300W <br /> and model#of PV (1) SMA SB 7.7-US <br /> modules and <br /> inverters): <br /> ©Determine if your project qualifies for expedited permitting: <br /> Yes No <br /> 1. PV system is designed and proposed for a detached one-or two-family dwelling or <br /> townhouse not more than three stories above grade or detached accessory structure that I , <br /> is code compliant to setbacks and height,or code allows expansion of nonconformity for �J <br /> solar modules. [IRC 101.2] <br /> 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by 0 <br /> the local jurisdiction. <br /> 3. Rooftop is made from lightweight material such as a single layer of composition shingles, <br /> metal roofing, lightweight masonry, or cedar shingles. 1 F3 <br /> 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2] lid ❑ <br /> 5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all _ <br /> required electrical permit(s) must be obtained from the Authority Having Jurisdiction to 1 <br /> administer the electrical code. [IRC M2302.2] <br /> 6. The installation shall meet the requirements of the International Fire Code as amended <br /> by WA State. [IRC M2302.2] <br /> 7. The PV system is designed for the wind speed of the local area, and will be installed per <br /> 0 <br /> the manufacturer's specifications. [IRC M2302.2.1(1)] <br /> 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] <br /> 9. Total dead load of modules,supports, mountings, raceways and all other appurtenances <br /> weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] [7 ❑ <br /> Enter total dead load of system (lbs/ft2): 2.7 <br /> 10. To address uplift, modules are mounted no higher than 18"above the surface of the (_l <br /> roofing to which they are affixed. [IRC M2302.2.1(4)] L_. <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.