- Simple Heating System Size: Washington State <br /> this heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 2435 <br /> Heating System Type: <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions ._-._.._. Design Temperature Difference(AT) 46 <br /> 1 Lynnwood <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 2,435 <br /> Average Ceiling Height Conditioned Volume <br /> instructions Average Ceiling Height(ft) 8.5 20,698 <br /> Glazing and Doors U-Factor X Area = UA <br /> nstructions 0.30 438 131.40 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions --_ ��---__--. <br /> R-49 ♦ 0.026 996 25.90 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions ___ <br /> ,,,,No Vaulted Ceilings in this project. V.� <br /> Above Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions """ ' <br /> R-21 0.056 2,500 140.00 <br /> Floors U-Factor Area UA <br /> Instructions `"` 0.029 470 13.63 <br /> 0 R-30 --y 1 <br /> Below Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions i- <br /> No Below Grade Walls in this project. V -, - <br /> Slab Below Grade(see Figure 1) F-Factor Length UA <br /> instructions <br /> No Slab Below Grade In this project. V 0111 <br /> Slab on Grade(see Figure 1) F-Factor Length UA <br /> Instructions <br /> 110 R-10 Perimeter V 0.540 82 44.28 <br /> Location of Ducts <br /> Instructions —_ Duct Leakage Coefficient <br /> Of Unconditioned Space .4 <br /> 1.10 <br /> Sum of UA 355.21 <br /> Envelope Heat Load 16,339 Btu I Hour <br /> Figure 1. Sum ofUAXAT <br /> Air Leakage Heat Load 10,283 Btu/Hour <br /> VolumeX 0.6XATX.018 <br /> Above Grade Building Design Heat Load 26,622 Btu/Hour <br /> '—"`,—,,, Air Leakage+Envelope Heat Loss <br /> ,,,-�-� <br /> • Building and Duct Heat Load 29,284 Btu/Hour <br /> Ducts in unconditioned space.Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X1 <br /> Maximum Heat Equipment Output 40,998 Btu/Hour ,/ <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace m Q <br /> Building and Duct Heat Loss X 1.25 for Heat Pump /(f <br /> (07/01/13) <br />