My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7806 19TH DR SE 2018-02-27
>
Address Records
>
19TH DR SE
>
7806
>
7806 19TH DR SE 2018-02-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2018 9:39:30 AM
Creation date
2/27/2018 9:39:18 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH DR SE
Street Number
7806
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling_ <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Kin'2435 <br /> Heating System Type: <br /> To see detailed instructions for each section,place your cursor on the word'Instructions". <br /> Design Temperature <br /> Instructions W-- Design Temperature Difference(AT) 46 <br /> nwood • <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> instructions Conditioned Floor Area(sq ft) 2,435 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 20,698 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions 0.30 <br /> ;,_� �;� 131.40 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions <br /> R 49 0.026 9911 25.90 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions <br /> ons No Vaulted Ceilings in this project • <br /> Above Grade Walls(see Figuret) U-Factor Area UA <br /> Instructions 0.056 2,500 140.00 <br /> Floors U-Factor Area UA <br /> Instructions <br /> -` " ` ` 0.029 '. 470 13.63 <br /> . R-30 �, • <br /> Below Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions <br /> No Below Grade Walls in this project. <br /> Slab Below Grade(see Figure 1 F-Factor Length UA <br /> Instructions "µ -- <br /> No Slab Below Grade In this project '► <br /> Slab on Grade(see Figure 1) F-Factor Length UA <br /> Instructions 0.540 82 44.28 <br /> R-10 Perimeter • <br /> Location of Ducts <br /> Instructions �•. — ._; Duct Leakage Coefficient <br /> Unconditioned Space1.10 <br /> Sum of UA 355.21 <br /> Envelope Heat Load 16,339 Btu/Hour <br /> Figure 1. sum of UAXAT <br /> Air Leakage Heat Load 10,283 Btu/Hour <br /> .4111111111111111101..- Volume X 0.6 X AT X.018 <br /> Building Design Heat Load 26,622 Btu/Hour <br /> ,,,„ Air Leakage+Envelope Heat Loss <br /> .•�^ Building and Duct Heat Load 29,284 Btu/Hour <br /> Dusts in unconditioned space:Sum of Building Heat Loss X 1.10 :71)Ducts in conditioned space:Sum of Building Heat Loss X <br /> Maximum Heat Equipment Output 40,998 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace y, <br /> Building and Duct Heat Loss X 1.25 for Heat Pump t / <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.