My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3428 FEDERAL AVE 2018-03-12
>
Address Records
>
FEDERAL AVE
>
3428
>
3428 FEDERAL AVE 2018-03-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2018 2:51:14 PM
Creation date
3/12/2018 2:51:10 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3428
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ffr <br /> POOLle WORKS <br /> January 30, 2016 <br /> Dante Palmaffy CD E IFOVEI <br /> 12925 47th Dr SE <br /> Everett WA 98208 FEB 1 7 2016 <br /> CITY OF EVERETT <br /> Subject: Project: CRMA INV. Permit Services <br /> Job Address: 3428 FederalAve <br /> Plan Check No: C1508-006 <br /> Dear Mr. Palmaffy: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2012 International Building Code,) (2012 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2012 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two copies of drawings reflecting the corrections <br /> requested,. <br /> L. Specify the height of the floor of the closet above the stairs to meet minimum <br /> headroom requirements. <br /> R311.7.2 headroom. <br /> The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 <br /> inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing <br /> or from the floor surface of the landing or platform on that portion of the stairway. <br /> 2. Winder treads shall be not less than 6 inches wide at the narrow side of the stairs. <br /> R311.7.5.2.1 Winder treads. <br /> Winder treads shall have a minimum tread depth of 10 inches (254 mm) measured <br /> between the vertical planes of the foremost projection of adjacent treads at the <br /> intersections with the walkline. Winder treads shall have a minimum tread depth of 6 <br /> inches (152 mm) at any point within the clear width of the stair. Within any flight of <br /> stairs, the largest winder tread depth at the walkline shall not exceed the smallest <br /> winder tread by more than /8 inch (9.5 mm). Consistently shaped winders at the <br /> ENGINgfigympojapg,www4smapptk,oggq„cedar Street•Everett,WA 98201 •(425)257-8800•Fax(425)257-8856 <br /> ;) <br />
The URL can be used to link to this page
Your browser does not support the video tag.